<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>2518-4431</journal-id>
<journal-title><![CDATA[Investigación & Desarrollo]]></journal-title>
<abbrev-journal-title><![CDATA[Inv. y Des.]]></abbrev-journal-title>
<issn>2518-4431</issn>
<publisher>
<publisher-name><![CDATA[UNIVERSIDAD PRIVADA BOLIVIANA]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S2518-44312026000100089</article-id>
<article-id pub-id-type="doi">10.23881/idupbo.026.1-5i</article-id>
<title-group>
<article-title xml:lang="en"><![CDATA[Performance Evaluation of a Full-Scale UASB-Activated Sludge System for Decentralized Domestic Wastewater Treatment]]></article-title>
<article-title xml:lang="es"><![CDATA[Evaluación del desempeño de un sistema UASB-lodos activados a escala real para el tratamiento descentralizado de aguas residuales domésticas]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Echeverría]]></surname>
<given-names><![CDATA[Ivette]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Escalera]]></surname>
<given-names><![CDATA[Ramiro]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Levy]]></surname>
<given-names><![CDATA[Alejandro]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Saavedra Valeriano]]></surname>
<given-names><![CDATA[Oliver C.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Universidad Privada Boliviana (UPB)  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>Bolivia</country>
</aff>
<aff id="Af2">
<institution><![CDATA[,Universidad Privada Boliviana (UPB)  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>Bolivia</country>
</aff>
<aff id="Af3">
<institution><![CDATA[,Fundación Aguatuya  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>Bolivia</country>
</aff>
<aff id="Af4">
<institution><![CDATA[,Universidad Privada Boliviana (UPB)  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>Bolivia</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>00</month>
<year>2026</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>00</month>
<year>2026</year>
</pub-date>
<volume>26</volume>
<numero>1</numero>
<fpage>89</fpage>
<lpage>103</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.bo/scielo.php?script=sci_arttext&amp;pid=S2518-44312026000100089&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.bo/scielo.php?script=sci_abstract&amp;pid=S2518-44312026000100089&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.bo/scielo.php?script=sci_pdf&amp;pid=S2518-44312026000100089&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="en"><p><![CDATA[Abstract: This study evaluated the performance of a full-scale wastewater treatment plant (WWTP) consisting of an upflow anaerobic sludge blanket (UASB) reactor followed by an activated sludge (AS) process for decentralized domestic wastewater treatment in a semi-arid region of Bolivia. The evaluation was based on nine monthly sampling campaigns of physicochemical monitoring, including wastewater quality, hydraulic and organic loading conditions, hydraulic retention time (HRT), mixed liquor suspended solids (MLSS), and food-to-microorganism (F/M) ratio. The system achieved overall removal efficiencies of 89% for BOD5, 88% for TCOD, 83% for SCOD, 89% for TSS, 67% for NH3-N, 64% for organic nitrogen (Norg), and 25% for soluble phosphorus (P), demonstrating effective removal of organic matter and suspended solids under partial hydraulic loading conditions. A simplified organic load balance showed that the treatment train reduced the average influent load from approximately 270 to 33 kg TCOD/d. A significant relationship was observed between settleable solids and MLSS concentrations (n=6, R2=0.798, p=0.016), suggesting that settleable solids may serve as simple complementary indicator of mixed liquor conditions. The fitted relationship yielded an exploratory, site-specific reference of approximately 471 mL/L of settleable solids corresponding to an MLSS concentration of 5 g/L. Operational indicators relevant to the management of decentralized wastewater treatment systems are also presented. The results demonstrate that the UASB-AS configuration can provide effective treatment performance and practical operational advantages for decentralized wastewater treatment systems operating under conditions similar to those evaluated in this study.]]></p></abstract>
<abstract abstract-type="short" xml:lang="es"><p><![CDATA[Resumen: Este estudio evaluó el desempeño de una planta de tratamiento de aguas residuales (PTAR) a escala real compuesta por un reactor anaerobio de flujo ascendente con manto de lodos (UASB) seguido de un proceso de lodos activados (AS) para el tratamiento descentralizado de aguas residuales domésticas en una región semiárida de Bolivia. La evaluación se basó en nueve meses de monitoreo fisicoquímico, incluyendo calidad del agua residual, condiciones de carga hidráulica y orgánica, tiempo de retención hidráulica (TRH), concentración de sólidos suspendidos en licor mezcla (MLSS) y relación alimento/microorganismo (F/M). El sistema alcanzó eficiencias globales de remoción de 89% para DBO5, 88% para DQO total, 83% para DQO soluble, 89% para SST, 67% para N-NH3, 64% para nitrógeno orgánico (Norg) y 25% para fósforo soluble (P), demostrando una remoción efectiva de materia orgánica y sólidos suspendidos bajo condiciones de carga hidráulica parcial. Un balance simplificado de carga orgánica mostró que el tren de tratamiento redujo la carga afluente promedio desde aproximadamente 270 hasta 33 kg DQO/d. Se observó una relación significativa entre los sólidos sedimentables y la concentración de MLSS (R2=0,798, p=0,016), lo que sugiere que los sólidos sedimentables pueden utilizarse como un indicador operacional práctico para la gestión de lodos. La relación obtenida indica que concentraciones de sólidos sedimentables cercanas a 470 mL/L pueden señalar valores de MLSS próximos o superiores al límite operacional recomendado de 5 g/L. Asimismo, se presentan indicadores operacionales relevantes para la gestión de sistemas descentralizados de tratamiento de aguas residuales. Los resultados demuestran que la configuración UASB-AS puede proporcionar un desempeño estable y ventajas operacionales prácticas para sistemas descentralizados de tratamiento de aguas residuales que operan bajo condiciones similares a las evaluadas en este estudio.]]></p></abstract>
<kwd-group>
<kwd lng="en"><![CDATA[UASB-activated sludge]]></kwd>
<kwd lng="en"><![CDATA[decentralized wastewater treatment]]></kwd>
<kwd lng="en"><![CDATA[full-scale WWTP]]></kwd>
<kwd lng="en"><![CDATA[operational performance]]></kwd>
<kwd lng="en"><![CDATA[domestic wastewater]]></kwd>
<kwd lng="es"><![CDATA[UASB-lodos activados]]></kwd>
<kwd lng="es"><![CDATA[tratamiento descentralizado de aguas residuales]]></kwd>
<kwd lng="es"><![CDATA[PTAR escala completa]]></kwd>
<kwd lng="es"><![CDATA[desempeño operacional]]></kwd>
<kwd lng="es"><![CDATA[aguas residuales domésticas]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="">
<collab>Ministerio de Medio Ambiente y Agua</collab>
<source><![CDATA[Estrategia Nacional de Tratamiento de Aguas Residuales (ENTAR)]]></source>
<year>2020</year>
</nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[McConville]]></surname>
<given-names><![CDATA[J. R.]]></given-names>
</name>
<name>
<surname><![CDATA[Künzle]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Messmer]]></surname>
<given-names><![CDATA[U.]]></given-names>
</name>
<name>
<surname><![CDATA[Udert]]></surname>
<given-names><![CDATA[K. M.]]></given-names>
</name>
<name>
<surname><![CDATA[Larsen]]></surname>
<given-names><![CDATA[T. A.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Decision support for redesigning wastewater treatment technologies]]></article-title>
<source><![CDATA[Environ. Sci. Technol.]]></source>
<year>2014</year>
<volume>48</volume>
<numero>20</numero>
<issue>20</issue>
<page-range>12238-46</page-range></nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Von Sperling]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<source><![CDATA[Urban wastewater treatment in Brazil]]></source>
<year>2016</year>
<publisher-name><![CDATA[Inter-American Development Bank]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="book">
<collab>CONAGUA</collab>
<source><![CDATA[Inventario Nacional de Plantas Municipales de Potabilización y de Tratamiento de Aguas Residuales en Operación]]></source>
<year>2022</year>
<publisher-loc><![CDATA[México ]]></publisher-loc>
<publisher-name><![CDATA[Comisión Nacional del Agua]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Khan]]></surname>
<given-names><![CDATA[A. A.]]></given-names>
</name>
<name>
<surname><![CDATA[Gaur]]></surname>
<given-names><![CDATA[R. Z.]]></given-names>
</name>
<name>
<surname><![CDATA[Lew]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
<name>
<surname><![CDATA[Diamantis]]></surname>
<given-names><![CDATA[V.]]></given-names>
</name>
<name>
<surname><![CDATA[Mehrotra]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
<name>
<surname><![CDATA[Kazmi]]></surname>
<given-names><![CDATA[A. A.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[UASB/Flash aeration enable complete treatment of municipal wastewater for reuse]]></article-title>
<source><![CDATA[Bioprocess Biosyst. Eng.]]></source>
<year>2012</year>
<volume>35</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>907-13</page-range></nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jafarinejad]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Cost estimation and economical evaluation of three configurations of activated sludge process for a wastewater treatment plant (WWTP) using simulation]]></article-title>
<source><![CDATA[Appl. Water Sci.]]></source>
<year>2017</year>
<volume>7</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>2513-21</page-range></nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Makwana]]></surname>
<given-names><![CDATA[A. R.]]></given-names>
</name>
<name>
<surname><![CDATA[Ahammed]]></surname>
<given-names><![CDATA[M. M.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Continuous electrocoagulation process for the post-treatment of anaerobically treated municipal wastewater]]></article-title>
<source><![CDATA[Process Saf. Environ. Prot.]]></source>
<year>2016</year>
<volume>102</volume>
<page-range>724-33</page-range></nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sikosana]]></surname>
<given-names><![CDATA[M. L.]]></given-names>
</name>
<name>
<surname><![CDATA[Sikhwivhilu]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
<name>
<surname><![CDATA[Moutloali]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Madyira]]></surname>
<given-names><![CDATA[D. M.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Municipal wastewater treatment technologies: A review]]></article-title>
<source><![CDATA[Procedia Manuf.]]></source>
<year>2019</year>
<volume>35</volume>
<page-range>1018-24</page-range></nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dohdoh]]></surname>
<given-names><![CDATA[A. M.]]></given-names>
</name>
<name>
<surname><![CDATA[Hendy]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
<name>
<surname><![CDATA[Zelenakova]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Abdo]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Domestic Wastewater Treatment: A Comparison between an Integrated Hybrid UASB-IFAS System and a Conventional UASB-AS System]]></article-title>
<source><![CDATA[Sustainability]]></source>
<year>2021</year>
<volume>13</volume>
<numero>4</numero>
<issue>4</issue>
</nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pfluger]]></surname>
<given-names><![CDATA[A. R.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Lifecycle Comparison of Mainstream Anaerobic Baffled Reactor and Conventional Activated Sludge Systems for Domestic Wastewater Treatment]]></article-title>
<source><![CDATA[Environ. Sci. Technol.]]></source>
<year>2018</year>
<volume>52</volume>
<numero>18</numero>
<issue>18</issue>
<page-range>10500-10</page-range></nlm-citation>
</ref>
<ref id="B11">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Von Sperling]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Freire]]></surname>
<given-names><![CDATA[V. H.]]></given-names>
</name>
<name>
<surname><![CDATA[De Lemos Chernicharo]]></surname>
<given-names><![CDATA[C. A.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Performance evaluation of a UASB - activated sludge system treating municipal wastewater]]></article-title>
<source><![CDATA[Water Sci. Technol.]]></source>
<year>2001</year>
<volume>43</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>323-8</page-range></nlm-citation>
</ref>
<ref id="B12">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pfluger]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Vanzin]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Munakata-Marr]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Figueroa]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[An anaerobic hybrid bioreactor for biologically enhanced primary treatment of domestic wastewater under low temperatures]]></article-title>
<source><![CDATA[Environ. Sci. Water Res. Technol.]]></source>
<year>2018</year>
<volume>4</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>1851-66</page-range></nlm-citation>
</ref>
<ref id="B13">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kassab]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Halalsheh]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Klapwijk]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Fayyad]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Van Lier]]></surname>
<given-names><![CDATA[J. B.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Sequential anaerobic&#8211;aerobic treatment for domestic wastewater &#8211; A review]]></article-title>
<source><![CDATA[Bioresour. Technol.]]></source>
<year>2010</year>
<volume>101</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>3299-310</page-range></nlm-citation>
</ref>
<ref id="B14">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Freire]]></surname>
<given-names><![CDATA[R. C.]]></given-names>
</name>
<name>
<surname><![CDATA[da Silva]]></surname>
<given-names><![CDATA[F. J. A.]]></given-names>
</name>
<name>
<surname><![CDATA[de O. Filho]]></surname>
<given-names><![CDATA[R. L.]]></given-names>
</name>
<name>
<surname><![CDATA[Targino]]></surname>
<given-names><![CDATA[J. M.]]></given-names>
</name>
<name>
<surname><![CDATA[Silva]]></surname>
<given-names><![CDATA[M. das G. M.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Desempenho de uma ete tipo uasb seguido de FSA (Estudo de Caso)]]></article-title>
<source><![CDATA[Braz. J. Dev.]]></source>
<year>2020</year>
<volume>6</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>102760-73</page-range></nlm-citation>
</ref>
<ref id="B15">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Khan]]></surname>
<given-names><![CDATA[A. A.]]></given-names>
</name>
<name>
<surname><![CDATA[Gaur]]></surname>
<given-names><![CDATA[R. Z.]]></given-names>
</name>
<name>
<surname><![CDATA[Mehrotra]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
<name>
<surname><![CDATA[Diamantis]]></surname>
<given-names><![CDATA[V.]]></given-names>
</name>
<name>
<surname><![CDATA[Lew]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
<name>
<surname><![CDATA[Kazmi]]></surname>
<given-names><![CDATA[A. A.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Performance assessment of different STPs based on UASB followed by aerobic post treatment systems]]></article-title>
<source><![CDATA[J. Environ. Health Sci. Eng.]]></source>
<year>2014</year>
<volume>12</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>43</page-range></nlm-citation>
</ref>
<ref id="B16">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mungray]]></surname>
<given-names><![CDATA[A. K.]]></given-names>
</name>
<name>
<surname><![CDATA[Patel]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Coliforms removal in two UASB + ASP based systems]]></article-title>
<source><![CDATA[Int. Biodeterior. Biodegrad.]]></source>
<year>2011</year>
<volume>65</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>23-8</page-range></nlm-citation>
</ref>
<ref id="B17">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Saliba]]></surname>
<given-names><![CDATA[P. D.]]></given-names>
</name>
<name>
<surname><![CDATA[Von Sperling]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Performance evaluation of a large sewage treatment plant in Brazil, consisting of an upflow anaerobic sludge blanket reactor followed by activated sludge]]></article-title>
<source><![CDATA[Water Sci. Technol.]]></source>
<year>2017</year>
<volume>76</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>2003-14</page-range></nlm-citation>
</ref>
<ref id="B18">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Oliveira]]></surname>
<given-names><![CDATA[S. C.]]></given-names>
</name>
<name>
<surname><![CDATA[von Sperling]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Performance evaluation of different wastewater treatment technologies operating in a developing country]]></article-title>
<source><![CDATA[J. Water Sanit. Hyg. Dev.]]></source>
<year>2011</year>
<volume>1</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>37-56</page-range></nlm-citation>
</ref>
<ref id="B19">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Echeverría]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
<name>
<surname><![CDATA[Saavedra]]></surname>
<given-names><![CDATA[O.]]></given-names>
</name>
<name>
<surname><![CDATA[Escalera]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Heredia]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Yoshimura]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Montoya]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Small-Scale Operation of an Integrated Anaerobic Baffled Reactor and Biofilter: Factors Affecting Its Performance]]></article-title>
<source><![CDATA[J. Environ. Eng.]]></source>
<year>2022</year>
<volume>148</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>04022065</page-range></nlm-citation>
</ref>
<ref id="B20">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Saavedra]]></surname>
<given-names><![CDATA[O.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Evaluation of a domestic wastewater treatment plant at an intermediate city in Cochabamba, Bolivia]]></article-title>
<source><![CDATA[Water Pract. Technol.]]></source>
<year>2019</year>
<volume>14</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>908-20</page-range></nlm-citation>
</ref>
<ref id="B21">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sundaresan]]></surname>
<given-names><![CDATA[N.]]></given-names>
</name>
<name>
<surname><![CDATA[Philip]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Performance evaluation of various aerobic biological systems for the treatment of domestic wastewater at low temperatures]]></article-title>
<source><![CDATA[Water Sci. Technol.]]></source>
<year>2008</year>
<volume>58</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>819-30</page-range></nlm-citation>
</ref>
<ref id="B22">
<nlm-citation citation-type="book">
<collab>Metcalf and Eddy</collab>
<source><![CDATA[Wastewater Engineering Treatment and Resource Recovery]]></source>
<year>2014</year>
<edition>Fifth edition</edition>
<publisher-name><![CDATA[Mc Graw Hill]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B23">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Henze]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Comeau]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Wastewater characterization]]></article-title>
<source><![CDATA[Biological Wastewater Treatment: Principles, Modelling and Design]]></source>
<year>2008</year>
<page-range>33-52</page-range><publisher-name><![CDATA[IWA Publishing]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B24">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Von Sperling]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Augusto De Lemos Chernicharo]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Urban wastewater treatment technologies and the implementation of discharge standards in developing countries]]></article-title>
<source><![CDATA[Urban Water]]></source>
<year>2002</year>
<volume>4</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>105-14</page-range></nlm-citation>
</ref>
<ref id="B25">
<nlm-citation citation-type="book">
<collab>United States Environmental Protection Agency (US EPA)</collab>
<source><![CDATA[Nutrient Control Design Manual]]></source>
<year>2010</year>
<publisher-loc><![CDATA[Cincinnati, OH / Washington, DC ]]></publisher-loc>
<publisher-name><![CDATA[U.S. EPA, Office of Research and Development, National Risk Management Research Laboratory]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B26">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[van Haandel]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[van der Lubbe]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Value and stability of the pH in anaerobic digesters]]></article-title>
<source><![CDATA[Anaerobic Sewage Treatment: Optimization of Process and Physical Design of Anaerobic and Complementary Processes]]></source>
<year>2019</year>
<publisher-name><![CDATA[IWA Publishing]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B27">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Elmitwalli]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Zeeman]]></surname>
<given-names><![CDATA[Gr.]]></given-names>
</name>
<name>
<surname><![CDATA[Lettinga]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Anaerobic treatment of domestic sewage at low temperature]]></article-title>
<source><![CDATA[Water Sci. Technol.]]></source>
<year>2001</year>
<volume>44</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>33-40</page-range></nlm-citation>
</ref>
<ref id="B28">
<nlm-citation citation-type="">
<source><![CDATA[Senamhi]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B29">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[De Lemos Chernicharo]]></surname>
<given-names><![CDATA[C. A.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Anaerobic Reactors]]></article-title>
<source><![CDATA[Biological Wastewater Treatment Series]]></source>
<year>2007</year>
<volume>4</volume>
<edition>1st ed</edition>
<publisher-name><![CDATA[IWA Publishing]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B30">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Díaz-Gómez]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Pérez-Vidal]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Vargas-Nuncira]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Usaquén-Perilla]]></surname>
<given-names><![CDATA[O.]]></given-names>
</name>
<name>
<surname><![CDATA[Jiménez-Daza]]></surname>
<given-names><![CDATA[X.]]></given-names>
</name>
<name>
<surname><![CDATA[Rodríguez]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Start-Up Evaluation of a Full-Scale Wastewater Treatment Plant Consisting of a UASB Reactor Followed by Activated Sludge]]></article-title>
<source><![CDATA[Water]]></source>
<year>2022</year>
<volume>14</volume>
<numero>24</numero>
<issue>24</issue>
</nlm-citation>
</ref>
<ref id="B31">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Daud]]></surname>
<given-names><![CDATA[M. K.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Review of Upflow Anaerobic Sludge Blanket Reactor Technology: Effect of Different Parameters and Developments for Domestic Wastewater Treatment]]></article-title>
<source><![CDATA[J. Chem.]]></source>
<year>2018</year>
<volume>2018</volume>
<page-range>1-13</page-range></nlm-citation>
</ref>
<ref id="B32">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Escalante]]></surname>
<given-names><![CDATA[V.]]></given-names>
</name>
<name>
<surname><![CDATA[Echeverría]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
<name>
<surname><![CDATA[Aliaga]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Heredia]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Escalera]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Saavedra]]></surname>
<given-names><![CDATA[O.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Evaluación comparativa de la gestión y costos en sistemas descentralizados de tratamiento de aguas residuales domésticas]]></article-title>
<source><![CDATA[Investig. Desarro.]]></source>
<year>2023</year>
<volume>23</volume>
<numero>1</numero>
<issue>1</issue>
</nlm-citation>
</ref>
<ref id="B33">
<nlm-citation citation-type="">
<collab>IBNORCA</collab>
<source><![CDATA[Norma Boliviana NB-EN 12255:6 Plantas de tratamiento de aguas residuales - Parte 6: Proceso de lodos activos]]></source>
<year>2022</year>
<publisher-loc><![CDATA[La Paz-Bolivia ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B34">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Daigger]]></surname>
<given-names><![CDATA[G. T.]]></given-names>
</name>
<name>
<surname><![CDATA[Redmond]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Downing]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Enhanced settling in activated sludge: design and operation considerations]]></article-title>
<source><![CDATA[Water Sci. Technol.]]></source>
<year>2018</year>
<volume>78</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>247-58</page-range></nlm-citation>
</ref>
<ref id="B35">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Yildiz]]></surname>
<given-names><![CDATA[B. S.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Water and wastewater treatment: biological processes]]></article-title>
<source><![CDATA[Metropolitan Sustainability]]></source>
<year>2012</year>
<page-range>406-28</page-range><publisher-name><![CDATA[Elsevier]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B36">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ahansazan]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
<name>
<surname><![CDATA[Afrashteh]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
<name>
<surname><![CDATA[Ahansazan]]></surname>
<given-names><![CDATA[N.]]></given-names>
</name>
<name>
<surname><![CDATA[Ahansazan]]></surname>
<given-names><![CDATA[Z.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Activated Sludge Process Overview]]></article-title>
<source><![CDATA[Int. J. Environ. Sci. Dev.]]></source>
<year>2014</year>
<volume>5</volume>
<numero>1</numero>
<issue>1</issue>
</nlm-citation>
</ref>
<ref id="B37">
<nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Richard]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Collins]]></surname>
<given-names><![CDATA[Fort]]></given-names>
</name>
</person-group>
<source><![CDATA[Activated Sludge Microbiology Problems and Their Control]]></source>
<year>2003</year>
</nlm-citation>
</ref>
<ref id="B38">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nielsen]]></surname>
<given-names><![CDATA[P. H.]]></given-names>
</name>
<name>
<surname><![CDATA[Keiding]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Disintegration of activated sludge flocs in presence of sulfide]]></article-title>
<source><![CDATA[Water Res.]]></source>
<year>1998</year>
<volume>32</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>313-20</page-range></nlm-citation>
</ref>
<ref id="B39">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jenkins]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Activated Sludge &#8211; 100 Years and Counting]]></article-title>
<source><![CDATA[Water Intell. Online]]></source>
<year>2014</year>
<volume>13</volume>
</nlm-citation>
</ref>
<ref id="B40">
<nlm-citation citation-type="">
<source><![CDATA[Ley N° 1333, Ley del Medio Ambiente]]></source>
<year>1992</year>
</nlm-citation>
</ref>
<ref id="B41">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Alvarez]]></surname>
<given-names><![CDATA[V.]]></given-names>
</name>
<name>
<surname><![CDATA[Buchauer]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
</person-group>
<source><![CDATA[East Asia and Pacific - Wastewater to energy processes: a technical note for utility managers in EAP countries]]></source>
<year>2015</year>
<publisher-name><![CDATA[World Bank]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B42">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bodík]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
<name>
<surname><![CDATA[Kubaská]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Energy and sustainability of operation of a wastewater treatment plant]]></article-title>
<source><![CDATA[Environ. Prot. Eng.]]></source>
<year>2013</year>
<volume>39</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>15-24</page-range></nlm-citation>
</ref>
<ref id="B43">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ranieri]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Giuliano]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Ranieri]]></surname>
<given-names><![CDATA[A. C.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Energy consumption in anaerobic and aerobic based wastewater treatment plants in Italy]]></article-title>
<source><![CDATA[Water Pract. Technol.]]></source>
<year>2021</year>
<volume>16</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>851-63</page-range></nlm-citation>
</ref>
<ref id="B44">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gu]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Energy Self-sufficient Wastewater Treatment Plants: Feasibilities and Challenges]]></article-title>
<source><![CDATA[Energy Procedia]]></source>
<year>2017</year>
<volume>105</volume>
<page-range>3741-51</page-range></nlm-citation>
</ref>
<ref id="B45">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Brault]]></surname>
<given-names><![CDATA[J.-M.]]></given-names>
</name>
<name>
<surname><![CDATA[Buchauer]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
<name>
<surname><![CDATA[Gambrill]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<source><![CDATA[Wastewater Treatment and Reuse: A Guide to Help Small Towns Select Appropriate Options]]></source>
<year>2022</year>
<publisher-name><![CDATA[World Bank]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B46">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Echeverría]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
</person-group>
<source><![CDATA[Ficha informativa: Planta de tratamiento de aguas residuales de Ucureña]]></source>
<year>2023</year>
<publisher-loc><![CDATA[Cochabamba, Bolivia ]]></publisher-loc>
<publisher-name><![CDATA[Fundación Aguatuya]]></publisher-name>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>