<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1024-0675</journal-id>
<journal-title><![CDATA[Revista de la Sociedad Boliviana de Pediatría]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. bol. ped.]]></abbrev-journal-title>
<issn>1024-0675</issn>
<publisher>
<publisher-name><![CDATA[Sociedad Boliviana de Pediatría]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1024-06752008000200010</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Respuesta broncodilatadora al salbutamol administrado como aerosol presurizado mediante aerocámaras con válvulas o espaciadores no valvulados]]></article-title>
<article-title xml:lang="en"><![CDATA[Bronchodilator response to salbutamol administered by MDI with a valved holding chamber vs. a non-valved spacer]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Kofman]]></surname>
<given-names><![CDATA[Carlos]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Teper]]></surname>
<given-names><![CDATA[Alejandro]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Vidaurreta]]></surname>
<given-names><![CDATA[Santiago]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Köhler]]></surname>
<given-names><![CDATA[María T.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,A01  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>06</month>
<year>2008</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>06</month>
<year>2008</year>
</pub-date>
<volume>47</volume>
<numero>2</numero>
<fpage>103</fpage>
<lpage>110</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.bo/scielo.php?script=sci_arttext&amp;pid=S1024-06752008000200010&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.bo/scielo.php?script=sci_abstract&amp;pid=S1024-06752008000200010&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.bo/scielo.php?script=sci_pdf&amp;pid=S1024-06752008000200010&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Introducción. Los medicamentos para tratar el asma utilizan fundamentalmente la vía inhalatoria. La utilidad de los espaciadores con válvulas (aerocámaras) está demostrada; sin embargo, recientemente se ha propuesto como alternativa más económica el uso de espaciadores sin válvulas. La e&#64257;cacia clínica de éstos no se ha demostrado hasta el momento. Objetivo. Comparar la respuesta broncodilatadora de un inhalador de dosis medida (IDM) de salbutamol administrado a través de una aerocámara contra un espaciador sin válvulas. Población, material y métodos. Estudio experimental, prospectivo, aleatorizado, simple ciego, de grupos paralelos. Se incluyeron 34 pacientes (6-16 años) con asma, que presentaban obstrucción bronquial leve o moderada (volumen respiratorio forzado, entre 50% y 79% del valor predictivo), sin haber recibido broncodilatadores recientemente. Luego de una espirometría inicial se asignaron para recibir 100 &#956;g de salbutamol (aerosol presurizado) mediante una aerocámara con válvulas (AerochamberMR) o un espaciador sin válvulas (Aeromed-MR). Se determinó la respuesta broncodilatadora del volumen respiratorio forzado y del FMF a los 30 minutos. Resultados. En el grupo con aerocámara ingresaron 17 pacientes (12 varones; volumen respiratorio forzado basal 67 ± 10%), y en el grupo con espaciador sin válvulas ingresaron 17 pacientes (13 varones, volumen respiratorio forzado basal 67 ± 6%). La variación del FEV1 fue 26 ± 14% contra 16 ± 5% (p= 0,017) y la variación del FMF fue 92 ± 48% contra 58 ± 29% (p= 0,018), para aerocámaras y espaciadores sin válvulas respectivamente (ANOVA). Conclusión. El aerosol presurizado de salbutamol administrado a través de una aerocámara con válvulas produce una respuesta broncodilatadora mayor que el espaciador sin válvulas en niños con asma.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Introduction. Inhalation therapy is the most frequent route for administration of asthma treatment. The utility of spacers added to metered dose inhalers (MDI) is well established. However, nonvalved spacers have recently been proposed as equally effective as the valved holding chambers, and more cost-effective. Clinical ef&#64257;cacy of nonvalved spacers is not well established yet. Objective. To compare the bronchodilator response to albuterol administered by MDI with a valved holding chamber vs. a non-valved spacer. Population, materials and methods. In an experimental, prospective, randomized, simple blind, parallel group study, 34 asthmatic children from 6 to 16 years old, with mild or moderate bronchial obstruction (forced expiratory volume in the &#64257;rst second, FEV1, 50 to 79% of predicted) without recent treatment with bronchodilating agents were randomly assigned to be treated with 100 &#956;g of albuterol MDI (Ventolin TM, MDI) either through a valved (AerochamberTM) or a non-valved (AeromedTM) spacer. After 30 minutes, bronchodilating response was determined through FEV1 and FMF measurements. Results. 17 patients used the valved holding chamber (12 male, baseline FEV1 67 ± 10%) and 17, the non-valved spacer (13 male, baseline FEV1 67 ± 6%). Variation of FEV1 was 26 ± 14% and 16±5% (p= 0.017) and variation of forced medium &#64258;ow (FMF) was 92 ± 48% and 58 ± 29% (p< 0.018) for the valved holding chamber and for the non-valved spacer, respectively (ANOVA test). Conclusion. Albuterol administered by MDI through a valved spacer produced a greater bronchodilator response than through a non-valved spacer in asthmatic children.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Rev Soc Bol Ped 2008]]></kwd>
<kwd lng="es"><![CDATA[47 (2): 103-10]]></kwd>
<kwd lng="es"><![CDATA[Espaciadores]]></kwd>
<kwd lng="es"><![CDATA[respuesta broncodilatadora]]></kwd>
<kwd lng="es"><![CDATA[asma]]></kwd>
<kwd lng="en"><![CDATA[Rev Soc Bol Ped 2008]]></kwd>
<kwd lng="en"><![CDATA[47 (2): 103-10]]></kwd>
<kwd lng="en"><![CDATA[Spacers]]></kwd>
<kwd lng="en"><![CDATA[bronchodilator response]]></kwd>
<kwd lng="en"><![CDATA[asthma]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <P align="right"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> <b>ARTICULOS DEL CONO SUR - ARGENTINA  </b></font></P> <b><font size="4" face="Verdana, Arial, Helvetica, sans-serif">Respuesta broncodilatadora al salbutamol administrado como aerosol presurizado mediante aeroc&aacute;maras con v&aacute;lvulas o espaciadores no valvulados<Sup>(1) </Sup> </font> </b>     <P align="justify"><b><em><font size="3" face="Verdana, Arial, Helvetica, sans-serif"> Bronchodilator response to salbutamol administered by MDI with a valved holding chamber vs. a non-valved spacer </font></em></b></P>     <p align="justify"><b><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Dres. Carlos Kofman*, Alejandro Teper*, Santiago Vidaurreta* y Mar&iacute;a T. K&ouml;hler* </font></b></p>     <p align="justify"><font size="1" face="Verdana, Arial, Helvetica, sans-serif">* Centro Respiratorio, Hospital de Ni&ntilde;os     <br> &ldquo;Dr. Ricardo Guti&eacute;rrez&rdquo;. Correspondencia: Dr. Carlos Kofman <a href="mailto:ckofman@gmail.com">ckofman@gmail.com</a> Con&#64258;icto de intereses y consideraciones &eacute;ticas: Este estudio no cont&oacute; con apoyo &#64257;nanciero para su realizaci&oacute;n y tuvo la aprobaci&oacute;n del Comit&eacute; de Docencia e Investigaci&oacute;n del Hospital de Ni&ntilde;os &ldquo;Dr. Ricardo Guti&eacute;rrez&rdquo;. </font></p>     <P align="justify"><font size="1" face="Verdana, Arial, Helvetica, sans-serif"> <b>(1) Art&iacute;culo original de Argentina, publicado en Archivos Argentinos de Pediatr&iacute;a: 2006; 104: 196-202 y que fue seleccionado para su reproducci&oacute;n en la XII Reuni&oacute;n de Editores de Revistas Pedi&aacute;tricas del Cono Sur. Bolivia 2007 </b></font></P> <hr> <font size="2" face="Verdana, Arial, Helvetica, sans-serif"><b>Resumen</b> </font>     <P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> <b>Introducci&oacute;n.</b> Los medicamentos para tratar el asma utilizan fundamentalmente la v&iacute;a inhalatoria. La utilidad de los espaciadores con v&aacute;lvulas (aeroc&aacute;maras) est&aacute; demostrada; sin embargo, recientemente se ha propuesto como alternativa m&aacute;s econ&oacute;mica el uso de espaciadores sin v&aacute;lvulas. La e&#64257;cacia cl&iacute;nica de &eacute;stos no se ha demostrado hasta el momento. </font></P>     <P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> <b>Objetivo.</b> Comparar la respuesta broncodilatadora de un inhalador de dosis medida (IDM) de salbutamol administrado a trav&eacute;s de una aeroc&aacute;mara contra un espaciador sin v&aacute;lvulas. </font></P>     <P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> <b>Poblaci&oacute;n, material y m&eacute;todos.</b> Estudio experimental, prospectivo, aleatorizado, simple ciego, de grupos paralelos. Se incluyeron 34 pacientes (6-16 a&ntilde;os) con asma, que presentaban obstrucci&oacute;n bronquial leve o moderada (volumen respiratorio forzado, entre 50% y 79% del valor predictivo), sin haber recibido broncodilatadores recientemente. Luego de una espirometr&iacute;a inicial se asignaron para recibir 100 &mu;g de salbutamol (aerosol presurizado) mediante una aeroc&aacute;mara con v&aacute;lvulas (AerochamberMR) o un espaciador sin v&aacute;lvulas (Aeromed-MR). Se determin&oacute; la respuesta broncodilatadora del volumen respiratorio forzado y del FMF a los 30 minutos. </font></P>     <P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> <b>Resultados.</b> En el grupo con aeroc&aacute;mara ingresaron 17 pacientes (12 varones; volumen respiratorio forzado basal 67 &plusmn; 10%), y en el grupo con espaciador sin v&aacute;lvulas ingresaron 17 pacientes (13 varones, volumen respiratorio forzado basal 67 &plusmn; 6%). La variaci&oacute;n del FEV1 fue 26 &plusmn; 14% contra 16 &plusmn; 5% (p= 0,017) y la variaci&oacute;n del FMF fue 92 &plusmn; 48% contra 58 &plusmn; 29% (p= 0,018), para aeroc&aacute;maras y espaciadores sin v&aacute;lvulas respectivamente (ANOVA). </font></P>     ]]></body>
<body><![CDATA[<P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> <b>Conclusi&oacute;n.</b> El aerosol presurizado de salbutamol administrado a trav&eacute;s de una aeroc&aacute;mara con v&aacute;lvulas produce una respuesta broncodilatadora mayor que el espaciador sin v&aacute;lvulas en ni&ntilde;os con asma. </font></P>     <P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> <b>Palabras clave: </b></font></P>     <P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> Rev Soc Bol Ped 2008; 47 (2): 103-10: Espaciadores, respuesta broncodilatadora, asma. </font></P> <hr> <font size="2" face="Verdana, Arial, Helvetica, sans-serif"><b>Summary</b> </font>     <P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> <b>Introduction.</b> Inhalation therapy is the most frequent route for administration of asthma treatment. The utility of spacers added to metered dose inhalers (MDI) is well established. However, nonvalved spacers have recently been proposed as equally effective as the valved holding chambers, and more cost-effective. Clinical ef&#64257;cacy of nonvalved spacers is not well established yet. </font></P>     <P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> <b>Objective.</b> To compare the bronchodilator response to albuterol administered by MDI with a valved holding chamber vs. a non-valved spacer. </font></P>     <P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> <b>Population, materials and methods.</b> In an experimental, </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">prospective, randomized, simple blind, parallel group study, 34 asthmatic children from 6 to 16 years old, with mild or moderate bronchial obstruction (forced expiratory volume in the &#64257;rst second, FEV1, 50 to 79% of predicted) without recent treatment with bronchodilating agents were randomly assigned to be treated with 100 &mu;g of albuterol MDI (Ventolin TM, MDI) either through a valved (AerochamberTM) or a non-valved (AeromedTM) spacer. After 30 minutes, bronchodilating response was determined through FEV1 and FMF measurements. </font></P>     <P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> <b>Results.</b> 17 patients used the valved holding chamber (12 male, baseline FEV1 67 &plusmn; 10%) and 17, the non-valved spacer (13 male, baseline FEV1 67 &plusmn; 6%). Variation of FEV1 was 26 &plusmn; 14% and 16&plusmn;5% (p= 0.017) and variation of forced medium &#64258;ow (FMF) was 92 &plusmn; 48% and 58 &plusmn; 29% (p&lt; 0.018) for the valved holding chamber and for the non-valved spacer, respectively (ANOVA test). </font></P>     <P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> <b>Conclusion.</b> Albuterol administered by MDI through a valved spacer produced a greater bronchodilator response than through a non-valved spacer in asthmatic children. </font></P> <font size="2" face="Verdana, Arial, Helvetica, sans-serif"><b>Key words: </b>  </font>     <P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> Rev Soc Bol Ped 2008; 47 (2): 103-10: Spacers, bronchodilator response, asthma. </font></P> <hr> <b><font size="3" face="Verdana, Arial, Helvetica, sans-serif">    <br> Introducci&oacute;n </font></b><font face="Verdana, Arial, Helvetica, sans-serif">     ]]></body>
<body><![CDATA[<P align="justify"><font size="2"> El asma es la enfermedad cr&oacute;nica m&aacute;s frecuente en pediatr&iacute;a, con una prevalencia en nuestro pa&iacute;s de 13 y 11% en las edades de 6 y 13 a&ntilde;os respectivamente.<Sup>1 </Sup></font></P>     <P align="justify"><font size="2"> La v&iacute;a inhalatoria ha demostrado ser la m&aacute;s adecuada para su tratamiento, ya que permite utilizar menos dosis de medicaci&oacute;n, con disminuci&oacute;n de la aparici&oacute;n de efectos colaterales.<Sup>2 </Sup></font></P>     <P align="justify"><font size="2"> Los sistemas de administraci&oacute;n inhalatoria disponibles son los nebulizadores, los aerosoles presurizados y los inhaladores de polvo seco.<Sup>3</Sup> La elecci&oacute;n del tipo de dispositivo depende de la situaci&oacute;n cl&iacute;nica, la edad del sujeto y las preferencias del m&eacute;dico y del paciente. Los aerosoles presurizados o inhaladores de dosis medida (IDM) son los sistemas m&aacute;s frecuentemente utilizados, aunque presentan el inconveniente que una proporci&oacute;n considerable de la dosis administrada puede depositarse en la orofaringe,<Sup>4</Sup> lo que determina la posibilidad de producir efectos adversos locales<Sup>5</Sup> y sist&eacute;micos.<Sup>6 </Sup></font></P>     <P align="justify"><font size="2"> Por otra parte, las di&#64257;cultades en la coordinaci&oacute;n entre la activaci&oacute;n o disparo del IDM y la inhalaci&oacute;n es un problema frecuente para muchos pacientes, especialmente en la edad pedi&aacute;trica.<Sup>7 </Sup></font></P>     <P align="justify"><font size="2"> Los intermediarios minimizan el dep&oacute;sito orofar&iacute;ngeo de las part&iacute;culas mediante la reducci&oacute;n del tama&ntilde;o y de la velocidad de su ingreso a las v&iacute;as a&eacute;reas.<Sup>8,9</Sup> Estos pueden ser simples espaciadores sin v&aacute;lvulas o aeroc&aacute;maras de contenci&oacute;n con v&aacute;lvulas. Existen modelos de aeroc&aacute;maras con una sola v&aacute;lvula inspiratoria y otros con dos, inspiratoria y espiratoria. A diferencia de los espaciadores sin v&aacute;lvulas, la funci&oacute;n adicional de las aeroc&aacute;maras valvuladas es la retenci&oacute;n del aerosol por un breve per&iacute;odo de tiempo luego de accionar el inhalador.<Sup>10 </Sup>Esto posibilita la inhalaci&oacute;n de mayor cantidad de part&iacute;culas, aunque la inspiraci&oacute;n no se produzca en forma sincr&oacute;nica con el disparo.<Sup>11 </Sup></font></P>     <P align="justify"><font size="2"> Para reducir los costos del tratamiento se ha propuesto la utilizaci&oacute;n de espaciadores caseros sin v&aacute;lvulas (ENV), suponiendo que su utilidad es an&aacute;loga a la de las aeroc&aacute;maras. Aunque algunos estudios observaron que la e&#64257;cacia, evaluada a trav&eacute;s de puntajes cl&iacute;nicos y mediciones de la funci&oacute;n pulmonar, es similar entre las nebulizaciones y los ENV en pacientes con obstrucci&oacute;n bronquial aguda,<Sup>12</Sup> no existen estudios que hayan comparado adecuadamente los cambios espirom&eacute;tricos que se producen entre los ENV y las aeroc&aacute;maras con v&aacute;lvulas. </font></P>     <P align="justify"><font size="2"> El objetivo del presente estudio fue comparar la respuesta broncodilatadora del salbutamol administrado mediante IDM con un espaciador con v&aacute;lvulas contra un ENV en ni&ntilde;os con asma. </font></P> <b><font size="3">    <br> Poblaci&oacute;n, material y m&eacute;todos </font></b><font size="2">     <P align="justify"> En un estudio experimental, prospectivo, aleatorizado, a simple ciego, de grupos paralelos, se incluyeron ni&ntilde;os entre 6 y 16 a&ntilde;os de edad, con diagn&oacute;stico con&#64257;rmado de asma,<Sup>13</Sup> que concurrieron al Centro Respiratorio del Hospital de Ni&ntilde;os &ldquo;Dr. Ricardo Guti&eacute;rrez&rdquo; para realizar una prueba de funci&oacute;n pulmonar entre octubre de 2003 y abril de 2004. Deb&iacute;an ser capaces de realizar una maniobra de espiraci&oacute;n forzada aceptable y reproducible (seg&uacute;n criterios de la American Thoracic Society)<Sup>14</Sup> y presentar un volumen espiratorio forzado en el primer segundo (volumen respiratorio forzado) entre el 50% y 79% del valor predictivo seg&uacute;n tablas de Knudson. Se utiliz&oacute; un Espir&oacute;metro Med-Graphics 1.070 Series 2. </P>     <P align="justify"> Se excluyeron los pacientes que hab&iacute;an recibido medicaci&oacute;n broncodilatadora de acci&oacute;n corta en las &uacute;ltimas 8 horas o de acci&oacute;n prolongada en las &uacute;ltimas 24 horas y los que hab&iacute;an presentado una crisis asm&aacute;tica moderada o grave en la semana anterior. </P>     ]]></body>
<body><![CDATA[<P align="justify"> Los pacientes se aleatorizaron mediante una tabla de n&uacute;meros aleatorios en bloques de a 10, para recibir salbutamol, aerosol presurizado con propelente HFA (VentolinMR, GSK Argentina): 1 disparo de 100 &mu;g a trav&eacute;s de una c&aacute;mara espaciadora pl&aacute;stica de 145 cm3 con m&aacute;scara facial y doble v&aacute;lvula unidireccional (AerochamberMR, Trudell, Ontario, Canad&aacute;) o un espaciador comercial pl&aacute;stico sin v&aacute;lvulas con salida tipo m&aacute;scara facial (AeromedMR, P Cassar&aacute;, Buenos Aires, Argentina). Los pacientes deb&iacute;an realizar 3 inhalaciones profundas y lentas por la boca con contenci&oacute;n de la respiraci&oacute;n durante por lo menos 8 segundos despu&eacute;s de cada una. El investigador que administraba la medicaci&oacute;n no participaba en la realizaci&oacute;n de la maniobra espiro-m&eacute;trica y, a su vez, el t&eacute;cnico encargado de realizar la espirometr&iacute;a desconoc&iacute;a el tipo de intermediario utilizado. </P> </font></font>      <P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> Las variaciones del volumen respiratorio forzado y del &#64258;ujo medio forzado (FMF) que se produjeron luego de 30 minutos de la administraci&oacute;n del salbutamol se consideraron las variables evaluadas. </font></P>     <P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> Para el an&aacute;lisis estad&iacute;stico del cambio de funci&oacute;n pulmonar se utiliz&oacute; el an&aacute;lisis de varianza de una v&iacute;a (ANOVA) a trav&eacute;s de un programa estad&iacute;stico computarizado (Systat). Se consider&oacute; signi&#64257;cativa una p&lt; 0,05. Los padres de los pacientes &#64257;rmaron un consentimiento escrito previo a la realizaci&oacute;n de los procedimientos. </font></P> <b><font size="3" face="Verdana, Arial, Helvetica, sans-serif">    <br> Resultados  </font> </b>     <P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> Ingresaron al estudio un total de 42 ni&ntilde;os que cumplieron con los criterios de inclusi&oacute;n y exclusi&oacute;n. Ocho no se incorporaron al an&aacute;lisis por errores en la t&eacute;cnica de inhalaci&oacute;n o por no realizar maniobras espirom&eacute;tricas aceptables y/o reproducibles. </font></P>     <P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> Se consideraron para el estudio 34 pacientes, 17 en el grupo con aeroc&aacute;mara con v&aacute;lvulas y 17 en el grupo ENV. Las caracter&iacute;sticas demogr&aacute;&#64257; cas de sexo y edad fueron similares en ambos grupos. Tampoco se encontraron diferencias signi&#64257;cativas entre los valores de funci&oacute;n pulmonar en el momento del ingreso entre las dos ramas de tratamiento, como se observa en la <a href="#t1">Tabla 1</a>. </font></P>     <P align="center"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><a name="t1"></a><img src="/img/revistas/rbp/v47n2/tabla10_1.gif" width="358" height="319"></font></P>     <P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> En la <a href="#f1">Figura 1</a> se aprecian los cambios individuales en el volumen respiratorio forzado de los pacientes incluidos en el estudio. </font></P>     <P align="center"><a name="f1"></a><img src="/img/revistas/rbp/v47n2/figura10_1.gif" width="357" height="328"></P>     <P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">La respuesta broncodilatadora del volumen respiratorio forzado (media &plusmn; </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">DE) fue de 25,6 &plusmn; 14% y 15,8 &plusmn; 5% para los grupos de pacientes tratados con aeroc&aacute;mara con v&aacute;lvulas y ENV, respectivamente. La diferencia entre ambos grupos fue estad&iacute;sticamente signi&#64257;cativa (p&lt; 0,017) (<a href="#f2">Figura 2</a>). </font></P>     ]]></body>
<body><![CDATA[<P align="center"><a name="f2"></a><img src="/img/revistas/rbp/v47n2/figura10_2.gif" width="352" height="302"></P>     <P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Asimismo, las variaciones individuales del FMF tambi&eacute;n fueron superiores para los pacientes del grupo con aeroc&aacute;mara de contenci&oacute;n (<a href="#f3">Figura 3</a>).</font></P>     <P align="center"><a name="f3"></a><img src="/img/revistas/rbp/v47n2/figura10_3.gif" width="363" height="310"></P>     <P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> La variaci&oacute;n del FMF (media &plusmn; DE) fue de 91,9 &plusmn; 49% y de 57,4 &plusmn; 29% para los grupos de ni&ntilde;os tratados mediante aeroc&aacute;mara de contenci&oacute;n y ENV, respectivamente (p= 0,018) (<a href="#f4">Figura 4</a>).</font></P>     <P align="center"><a name="f4"></a><img src="/img/revistas/rbp/v47n2/figura10_4.gif" width="356" height="309"></P>     <P align="left"><b><font size="3" face="Verdana, Arial, Helvetica, sans-serif">    <br> Discusi&oacute;n</font></b></P>     <P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> El presente estudio se llev&oacute; a cabo para evaluar, a trav&eacute;s de la funci&oacute;n pulmonar, la e&#64257;cacia y la e&#64257;ciencia de los espaciadores no valvulados comparados con las aeroc&aacute;maras de contenci&oacute;n. Los resultados obtenidos demuestran que la respuesta broncodilatadora del salbutamol inhalado mediante un aerosol presurizado y una aeroc&aacute;mara es mayor que la administraci&oacute;n de la misma medicaci&oacute;n a trav&eacute;s de un ENV en ni&ntilde;os con asma y obstrucci&oacute;n bronquial. </font></P>     <P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">La utilizaci&oacute;n de los IDM sin espaciadores produce   una elevada deposici&oacute;n orofar&iacute;ngea del aerosol<sup>15</sup> permitiendo su degluci&oacute;n y absorci&oacute;n digestiva, lo   cual incrementa signifi cativamente la incidencia de   los efectos sist&eacute;micos. Adem&aacute;s, muchos pacientes   presentan grandes difi cultades para llevar a cabo la   maniobra inhalatoria correcta<sup>16</sup> y ello disminuye la   efectividad del tratamiento. Los diversos modelos   de intermediarios difi eren considerablemente en dise&ntilde;o,   tama&ntilde;o, material y precio. Distintos estudios   han evaluado la efi cacia de las aeroc&aacute;maras para   generar aerosoles con part&iacute;culas en rango respirable   (di&aacute;metro inferior a 4,7 micrones),<sup>17-19</sup> reducir el dep&oacute;sito   orofar&iacute;ngeo<sup>20-22</sup> y para mantener una correcta   administraci&oacute;n de part&iacute;culas aun cuando el IDM se   accione en forma no coordinada con la inspiraci&oacute;n.<sup>23-   25</sup> En los sistemas de aeroc&aacute;maras de contenci&oacute;n, la   v&aacute;lvula inspiratoria se cierra durante la espiraci&oacute;n,   evitando la p&eacute;rdida de aerosol por la parte posterior y   la entrada de aire exhalado hacia la c&aacute;mara, mientras   que las part&iacute;culas permanecen en suspensi&oacute;n hasta la   inhalaci&oacute;n siguiente.<sup>26</sup> Los espaciadores sin v&aacute;lvulas,   por el contrario, no impiden completamente la llegada   de part&iacute;culas de mayor tama&ntilde;o que a alta velocidad   impactan inercialmente contra la pared posterior   de la orofaringe. Asimismo, el fl ujo espiratorio del   paciente puede arrastrar las part&iacute;culas remanentes en   el intermediario hacia el exterior a trav&eacute;s del espacio   que existe entre el envase y la carcasa pl&aacute;stica del inhalador   o entre la carcasa y el orificio del espaciador donde se coloca el IDM.</font></P>      <P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> Un IDM de 100 &mu;g de salbutamol usado en forma aislada administra una dosis contenida en el rango de part&iacute;culas respirables de 50 a 60 &mu;g/disparo.<sup>19</sup> Aunque todos los intermediarios disminuyen en mayor o menor medida el dep&oacute;sito orofar&iacute;ngeo, esta disminuci&oacute;n a veces se produce a expensas de una menor cantidad de medicaci&oacute;n que emiten algunos sistemas. Mediante la relaci&oacute;n de dep&oacute;sito pulmonar/dep&oacute;sito orofar&iacute;ngeo, midiendo el tama&ntilde;o de part&iacute;culas in vitro con impactadores de cascada, se puede cuanti&#64257;car la e&#64257;ciencia de los sistemas para evaluar la reducci&oacute;n del dep&oacute;sito en la v&iacute;a a&eacute;rea superior, manteniendo una adecuada dosis en rango respirable. Wilkes y col.<Sup>27</Sup> demostraron as&iacute; que las aeroc&aacute;maras con v&aacute;lvulas proveen los mayores incrementos (8 a 10 veces) de esa relaci&oacute;n. </font></P>     ]]></body>
<body><![CDATA[<P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> En muchos casos, especialmente en los pa&iacute;ses subdesarrollados, es dif&iacute;cil la adquisici&oacute;n de aeroc&aacute;maras comerciales con v&aacute;lvulas debido a su costo. Por tal motivo, es frecuente la confecci&oacute;n de espaciado-res caseros con distintas alternativas, como botellas pl&aacute;sticas de gaseosa, envases de suero, vasos pl&aacute;sticos, etc. Asimismo, en a&ntilde;os recientes han aparecido en el mercado espaciadores comerciales sin v&aacute;lvulas de bajo costo. Sin embargo, en la literatura m&eacute;dica no existe informaci&oacute;n su&#64257;ciente sobre la verdadera utilidad cl&iacute;nica de este tipo de espaciadores. </font></P>     <P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> Algunos estudios <i>in vitro</i> han evaluado la dispersi&oacute;n del tama&ntilde;o de las part&iacute;culas que generan los intermediarios simples sin v&aacute;lvulas. En el estudio de Wilkes<sup>27</sup> se estableci&oacute; que todos los espacia-dores, incluidos los ENV, reducen el tama&ntilde;o de las part&iacute;culas que suministra el IDM. Sin embargo, la dosis administrada en el rango respirable, la relaci&oacute;n dep&oacute;sito pulmonar/dep&oacute;sito orofar&iacute;ngeo y la e&#64257;ciencia del sistema cuando existe incoordinaci&oacute;n entre el disparo y la inspiraci&oacute;n, di&#64257; eren considerablemente entre los espaciadores considerados. La relaci&oacute;n dep&oacute;sito pulmonar/dep&oacute;sito orofar&iacute;ngeo del IDM sin ning&uacute;n intermediario es menor de 4. Un tubo simple de cart&oacute;n la eleva a 18, mientras que las aeroc&aacute;maras alcanzan valores mayores de 35. Sin embargo, otro estudio in vitro encontr&oacute; que botellas pl&aacute;sticas de diferentes tama&ntilde;os presentaban una dispersi&oacute;n aceptable del tama&ntilde;o de part&iacute;culas, similar a la de un espaciador valvulado.<Sup>28</Sup> Otra manera de evaluar el comportamiento de los sistemas inhalatorios es mediante centellogramas de ventilaci&oacute;n pulmonar con part&iacute;culas marcadas con radiois&oacute;topos. De esta forma, Zar y col.,<Sup>29</Sup> han demostrado que espaciadores confeccionados con botellas pl&aacute;sticas de 500 cm<Sup>3</Sup> permiten un dep&oacute;sito pulmonar similar al de las aeroc&aacute;maras comerciales. Una tercera forma de evaluaci&oacute;n se basa en la medici&oacute;n de la concentraci&oacute;n plasm&aacute;tica de ciertas medicaciones luego de su administraci&oacute;n inhalatoria. Debido a que la biodisponibilidad del salbutamol est&aacute; en relaci&oacute;n directa con la penetraci&oacute;n de la medicaci&oacute;n en las v&iacute;as a&eacute;reas distales, se la puede aprovechar para comparar la e&#64257;ciencia entre sistemas. Fowler y col.,<Sup>30 </Sup>demostraron por este m&eacute;todo que las concentraciones m&aacute;xima y media de salbutamol que se alcanza con una aeroc&aacute;mara valvulada es mayor que cuando se administra una dosis similar con un ENV o sin ning&uacute;n espaciador. </font></P>     <P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">La mayor&iacute;a de las experiencias que se realizan <i>in vitro</i> y las que se realizan en sujetos que no representan exactamente las condiciones cl&iacute;nicas de un enfermo deben ser complementadas por evaluaciones de e&#64257;cacia cl&iacute;nica o por estudios de respuesta de la funci&oacute;n pulmonar.<Sup>31,32 </Sup>Son escasos los estudios cient&iacute;&#64257;cos publicados en la literatura m&eacute;dica que eval&uacute;an la respuesta cl&iacute;nica y funcional respiratoria de los ENV. Rajkumar y col.,<Sup>33</Sup> han publicado que los espaciadores caseros de botella son igualmente efectivos que los espaciadores comerciales con v&aacute;lvulas para producir una respuesta broncodilatadora. Sin embargo, este estudio presenta un error metodol&oacute;gico, ya que el n&uacute;mero de pacientes estudiados no fue su&#64257;ciente como para poder aseverar sus resultados. Asimismo, Singhal y col.<Sup>34</Sup> y Panicker y col.,<Sup>35</Sup> no observaron diferencias de la saturaci&oacute;n arterial de ox&iacute;geno y del &#64258;ujo pico espiratorio entre pacientes que presentaban crisis agudas de obstrucci&oacute;n bronquial y que fueron tratados mediante espaciadores caseros o aeroc&aacute;maras comerciales. En estos casos, la similitud entre los tratamientos se debi&oacute; principalmente a la utilizaci&oacute;n de altas dosis de broncodilatadores (1.000 &mu;g de salbutamol) y a que tanto la saturaci&oacute;n arterial de ox&iacute;geno como la medici&oacute;n del &#64258;ujo pico espiratorio no son variables de su&#64257;ciente sensibilidad. Del mismo modo, Zar y col.<Sup>36</Sup> encontraron que una aeroc&aacute;mara con v&aacute;lvulas y una botella pl&aacute;stica de 500 cm3 producen una broncodilataci&oacute;n equivalente medida a trav&eacute;s de un puntaje cl&iacute;nico y de la espirometr&iacute;a en ni&ntilde;os asm&aacute;ticos con obstrucci&oacute;n bronquial moderada a grave. Este estudio tambi&eacute;n se realiz&oacute; con dosis elevadas de broncodilatadores (400 a 600 &mu;g de fenoterol). La administraci&oacute;n de broncodilatadores en altas dosis determina que la respuesta cl&iacute;nica o funcional sea similar, aun con sistemas de diferente e&#64257;ciencia. </font></P>     <P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> En estos casos, la dosis pulmonar de ambos es su&#64257;ciente como para alcanzar el punto en el cual la curva dosis/respuesta no permite demostrar la diferencia. En nuestro estudio decidimos utilizar la dosis de 100 &mu;g de salbutamol, que es la mitad de la que se utiliza habitualmente en los estudios funcionales de rutina para poder objetivar la diferencia entre ambos m&eacute;todos de administraci&oacute;n. Por lo tanto, creemos que los ENV son efectivos para la administraci&oacute;n de altas dosis de broncodilatadores, pero ine&#64257; cientes si se los compara con aeroc&aacute;maras de contenci&oacute;n. </font></P>     <P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> Un factor de considerable importancia para la &oacute;ptima llegada de part&iacute;culas a las v&iacute;as a&eacute;reas es la coordinaci&oacute;n entre el accionamiento del IDM y la inspiraci&oacute;n. Cuando se utiliza un ENV, la reducci&oacute;n de la dosis pulmonar es relevante (dos tercios) si el paciente retarda la inhalaci&oacute;n s&oacute;lo 1 segundo con respecto al disparo.<Sup>27</Sup> M&aacute;s a&uacute;n, si el accionamiento se produce durante la exhalaci&oacute;n, el dep&oacute;sito pulmonar cae dr&aacute;sticamente 80 a 90% con respecto al que se alcanzar&iacute;a en forma sincr&oacute;nica. En cambio, si se utilizan aeroc&aacute;maras con v&aacute;lvulas, la in&#64258;uencia del momento del disparo es menos signi&#64257;cativa. Dolovich y col.,<Sup>23</Sup> apreciaron que la reducci&oacute;n de la dosis pulmonar utilizando una c&aacute;mara de retenci&oacute;n cuando se acciona en forma no sincronizada es de s&oacute;lo el 15%. Por otra parte, en presencia de obstrucci&oacute;n bronquial es m&aacute;s probable que el paciente accione el inhalador durante la espiraci&oacute;n.8 Por lo tanto, en sujetos con crisis obstructivas la administraci&oacute;n de dosis adecuadas de broncodilatadores es mejor con las aeroc&aacute;maras valvuladas que con los ENV o IDM sin intermediarios.<Sup>37,38 </Sup></font></P>     <P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> El presente estudio permite establecer que, en ni&ntilde;os con asma, las variaciones del volumen respiratorio forzado y del FMF son mayores cuando el aerosol presurizado de salbutamol se administra a trav&eacute;s de una aeroc&aacute;mara con v&aacute;lvulas que con un espaciador sin v&aacute;lvulas. Si bien nuestros resultados no se pueden extender sistem&aacute;ticamente al uso de los corticoides inhalados, especulamos que su utilizaci&oacute;n a largo plazo con espaciadores ine&#64257;cientes aumentar&iacute;a el desperdicio de la medicaci&oacute;n, con requerimiento de dosis mayores y aumento del costo &#64257;nal del tratamiento. Se requieren nuevos estudios cl&iacute;nicos para demostrar esta especulaci&oacute;n. </font></P> <b><font size="3" face="Verdana, Arial, Helvetica, sans-serif">    <br> Conclusi&oacute;n </font> </b>     <P align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> En ni&ntilde;os con asma, la variaci&oacute;n de los par&aacute;metros espirom&eacute;tricos de obstrucci&oacute;n bronquial es mayor cuando el aerosol presurizado de salbutamol se administra a trav&eacute;s de una aeroc&aacute;mara con v&aacute;lvulas que con un espaciador sin v&aacute;lvulas. </font></P> <b><font size="3" face="Verdana, Arial, Helvetica, sans-serif">    <br> Bibliograf&iacute;a </font> </b>     <!-- ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">   1. Mallol J, Sole D, Asher I, Clayton T, Stein R, Soto-Quiroz M. Prevalence of asthma symptoms in Latin America: the International Study of Asthma and Allergies in Childhood (ISAAC). Pediatr Pulmonol 2000; 30:439-44. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=408640&pid=S1024-0675200800020001000001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">   2. Dalby R, Suman J. Inhalation therapy: technological milestones in asthma treatment. Ad Drug Delivery Rev 2003; 55:779-791. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=408641&pid=S1024-0675200800020001000002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> 3. Kofman C, Berlinski A. Aerosolterapia. En: Enfermedades Respiratorias Pedi&aacute;tricas. Editores Macri CN, Teper AM. Buenos Aires: Mc Graw Hill, 2003:777-784. </font></p>     <!-- ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">   4. Kim C, Eldridge MA, Sackner MA. Oropharyngeal deposition and delivery aspects of metered-dose inhaler aerosols. Am Rev Respir Dis 1987; 135:157- 164. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=408643&pid=S1024-0675200800020001000004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">   5. Toogood JH, Jennings B, Greenway RW, Chuang L. Candidiasis and dysphonia complicating beclomethasone treatment of asthma. J Allergy Clin Immunol 1980; 65:145-153. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=408644&pid=S1024-0675200800020001000005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">   6. Pescollderungg I, Radetti G, Gottardi E, Peroni DG, Pietrobelli A, Boner AL. Systemic activity of inhaled corticosteroid treatment in asthmatic children: corticotrophin releasing hormone test. Thorax 2003; 58:227-230. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=408645&pid=S1024-0675200800020001000006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">   7. Kofman C, Berlinski A, Zaragoza S, Teper A. Aerosol therapy for pediatric outpatients. J Resp Care Pract (ISSN 1040-6050) 2004; page 26. </font></p>     <!-- ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">   8. Tobin MJ, Jenouri G, Danta I, Kim C, Watson H, Sackner MA. Response to bronchodilator drug administration by a new reservoir aerosol delivery system and a review of other auxiliary delivery systems. Am Rev Respir Dis 1982; 126:670-675. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=408647&pid=S1024-0675200800020001000008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> 9. Newhouse MT, Ruf&#64257;n RE. Deposition and fate of aerosolized drugs. Chest 1978; 6:939-943. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=408648&pid=S1024-0675200800020001000009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">   10. Bruce K. Rubin. Inhaled corticosteroids: devices and deposition. Paed Resp Rev 2004; 5(Suppl A):S103-S106. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=408649&pid=S1024-0675200800020001000010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">   11. Dolovich MB. Lung dose, distribution and clinical response to therapeutic aerosols. Aerosol Sci Technol 1993; 18:230-40. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=408650&pid=S1024-0675200800020001000011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> 12. Duarte M, Camargos P. Ef&#64257;cacy and safety of a homemade non-valved spacer for bronchodilator therapy in acute asthma. Acta Paediatr 2002; 91:909-13. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=408651&pid=S1024-0675200800020001000012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">   13. GINA (Global Initiative for Asthma). Global Strategy for Asthma Management and Prevention. NIH Publication No 02-3659 Issued January, 1995 (updated 2002). Disponible en http://www.ginasthma.com </font></p>     <p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">   14. Standardization of Spirometry, 1994 Update. American Thoracic Society. Am J Respir Crit Care Med 1995; 152:1107-36. </font></p>     <!-- ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> 15. Schultz RK. Drug delivery characteristics of metered dose inhalers. J Allergy Clin Immunol 1995; 96:284-287. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=408654&pid=S1024-0675200800020001000015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">   16. McFadden Jr ER. Improper patient techniques with metered dose inhalers: Clinical consequences and solutions to misuse. J Allergy Clin Immunol 1995; 96:278-283. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=408655&pid=S1024-0675200800020001000016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> 17. Ahrens R, Lux C, Bahl T, Han SH. Choosing the metered dose inhaler spacer or holding chamber that matches the patient&rsquo;s need: evidence that the speci&#64257;c drug being delivered is an important consideration. J Allergy Clin Immunol 1995; 96:288&ndash; 294. </font></p>     <p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> 18. Barry PW, O&rsquo;Callaghan C. Inhalation drug delivery from seven different spacer devices. Thorax 1996; 51:835-840. </font></p>     <!-- ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">   19. Finlay WH, Zuberbuhler P, Mandl M. Particle size measurements for the space-chamber metered dose inhaler holding chamber compared with aerochamber and metered dose inhaler alone. J Aerosol Med 1997; 10:213-219. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=408658&pid=S1024-0675200800020001000019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">   20. Newman SP, Moren F, Pavia D, Little F, Clarke SW. Deposition of pressurized suspension aerosols inhaled through extension devices. Am Rev Respir Dis 1981; 124:317-320. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=408659&pid=S1024-0675200800020001000020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> 21. Dolovich M, Ruf&#64257;n R, Corr D, Newhouse MT. Clinical evaluation of a simple demand inhalation MDI aerosol delivery device. Chest 1983; 84:36-41. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=408660&pid=S1024-0675200800020001000021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> 22. Kim C, Eldridge MA, Sackner MA. Oropharyngeal deposition and delivery aspects of metered-dose inhaler aerosols. Am Rev Respir Dis 1987; 135:157&ndash; 164. </font></p>     <p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">   23. Dolovich M, Chambers C. Effect of a pause prior to inhaling a MDI aerosol on drug availability through an open tube spacer [Abstract]. J Allergy Clin Immunol 1994; 93:A39. </font></p>     <p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> 24. Barry PW, O&rsquo;Callaghan C. The effect of delay, multiple actuations and spacer charge on the in vitro delivery of budesonide from the Nebuhaler. Br J Clin Pharmacol 1995; 40:76-78. </font></p>     <!-- ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> 25. Wildhaber JH, Devadason SG, Eber E, Hayden MJ, Everard ML, Summers QA, LeSouef PN. Effect of electrostatic charge, &#64258;ow, delay and multiple actuations on the in vitro delivery of salbutamol from different spacer devices. Thorax 1996; 51:985- 988. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=408664&pid=S1024-0675200800020001000025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> 26. Barry PW, Robertson CF, O&rsquo;Callaghan C. Optimum use of a spacer device. Arch Dis Child 1993; 69:693-694. </font></p>     <!-- ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> 27. Wilkes W, Fink J, Dhand R. Selecting an accessory device with a metered-dose inhaler: Variable in&#64258;uence of accessory devices on &#64257;ne particle dose, throat deposition, and drug delivery with asynchronous actuation from a metered-dose inhaler. J Aerosol Med 2001; 14:351-360. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=408666&pid=S1024-0675200800020001000027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">   28. Kissoon N, Teelucksingh S, Blake KV, Kesser B, Murphy SP, Geller D. Plastic bottles as spacers for a pressurized metered-dose inhaler: in vitro characteristics. West Indian Med J 2001; 50:189-93. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=408667&pid=S1024-0675200800020001000028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">   29. Zar HJ, Weinberg EG, Binns HJ, Gallie F, Mann MD. Lung deposition of aerosol. A comparison of different spacers. Arch Dis Child 2000; 82:495-498. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=408668&pid=S1024-0675200800020001000029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> 30. Fowler SJ, Wilson AM, Grif&#64257;ths EA, Lipworth BJ. Comparative in vivo lung delivery of hydro&#64258;uoroalkane salbutamol formulation via metered-dose inha   ler alone, with plastic spacer, or with cardboard tube. Chest 2001; 119:1018-1020. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=408669&pid=S1024-0675200800020001000030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">   31. Dolovich MB, Ahrens RC, Hess DR, Anderson P, Dhand R, Rau JL, Smaldone GC, Guyatt G. American College of Chest Physicians, American College of Asthma, Allergy, and Immunology. Device selection and outcomes of aerosol therapy: ACCP/ACAAI evidence-base guidelines. Chest 2005; 127:335-71. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=408670&pid=S1024-0675200800020001000031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> 32. Dubus JC, Dolovich M. Emitted doses of salbutamol pressurized metered-dose inhaler from &#64257; ve different plastic spacer devices. Fundam Clin Pharmacol 2000; 14:219-24. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=408671&pid=S1024-0675200800020001000032&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">   33. Rajkumar, Vatsa HK, Gaur SN. Comparative evaluation of market spacer and home made spacer in the management of bronchial asthma. J Assoc Physicians India 2002; 50:397-9. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=408672&pid=S1024-0675200800020001000033&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> 34. Singhal T, Garg H, Arora HS, Lodha R, Pandey RM, Kabra SK. Ef&#64257;cacy of a home-made spacer    with acute exacerbation of bronchial asthma: a randomized controlled trial. Indian J Pediatr 2001; 68:37-40. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=408673&pid=S1024-0675200800020001000034&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> 35. Panicker J, Sethi GR, Sehgal V.	 Comparative ef&#64257;ciency of commercial and improvised spacer device in acute bronchial asthma. Indian Pediatrics 2001; 38:340-348. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=408674&pid=S1024-0675200800020001000035&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">   36. Zar HJ, Brown G, Donson H, Brathwaite N, Mann MD, Weinberg EG. Home-made spacers for bronchodilator therapy in children with acute asthma: a randomized trial. Lancet 1999; 354:979- 982. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=408675&pid=S1024-0675200800020001000036&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> 37. Fink J, Dhand R. Bronchodilator resuscitation in the emergency department: device selection. Respir Care 1999; 44:1353&ndash;1374. </font></p>     <!-- ref --><p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">   38. Amirav I, Newhouse MT. Metered-dose inhaler accessory devices in acute asthma. Arch Pediatr Adolesc Med 1997; 151:876-882. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=408677&pid=S1024-0675200800020001000038&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mallol]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Sole]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Asher]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Clayton]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Stein]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Soto Quiroz]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Prevalence of asthma symptoms in Latin America: the International Study of Asthma and Allergies in Childhood (ISAAC)]]></article-title>
<source><![CDATA[Pediatr Pulmonol]]></source>
<year>2000</year>
<volume>30</volume>
<page-range>439-44</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dalby]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Suman]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Inhalation therapy: technological milestones in asthma treatment]]></article-title>
<source><![CDATA[Ad Drug Delivery Rev]]></source>
<year>2003</year>
<volume>55</volume>
<page-range>779-791</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kofman]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Berlinski]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Aerosolterapia]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Macri]]></surname>
<given-names><![CDATA[CN]]></given-names>
</name>
<name>
<surname><![CDATA[Teper]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
</person-group>
<source><![CDATA[Enfermedades Respiratorias Pediátricas]]></source>
<year>2003</year>
<page-range>777-784</page-range><publisher-loc><![CDATA[Buenos Aires ]]></publisher-loc>
<publisher-name><![CDATA[Mc Graw Hill]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kim]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Eldridge]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
<name>
<surname><![CDATA[Sackner]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Oropharyngeal deposition and delivery aspects of metered-dose inhaler aerosols]]></article-title>
<source><![CDATA[Am Rev Respir Dis]]></source>
<year>1987</year>
<volume>135</volume>
<page-range>157-164</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Toogood]]></surname>
<given-names><![CDATA[JH]]></given-names>
</name>
<name>
<surname><![CDATA[Jennings]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Greenway]]></surname>
<given-names><![CDATA[RW]]></given-names>
</name>
<name>
<surname><![CDATA[Chuang]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Candidiasis and dysphonia complicating beclomethasone treatment of asthma]]></article-title>
<source><![CDATA[J Allergy Clin Immunol]]></source>
<year>1980</year>
<volume>65</volume>
<page-range>145-153</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pescollderungg]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Radetti]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Gottardi]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Peroni]]></surname>
<given-names><![CDATA[DG]]></given-names>
</name>
<name>
<surname><![CDATA[Pietrobelli]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Boner]]></surname>
<given-names><![CDATA[AL]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Systemic activity of inhaled corticosteroid treatment in asthmatic children: corticotrophin releasing hormone test]]></article-title>
<source><![CDATA[Thorax]]></source>
<year>2003</year>
<volume>58</volume>
<page-range>227-230</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kofman]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Berlinski]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Zaragoza]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Teper]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Aerosol therapy for pediatric outpatients]]></article-title>
<source><![CDATA[J Resp Care Pract]]></source>
<year>2004</year>
<page-range>26</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tobin]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
<name>
<surname><![CDATA[Jenouri]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Danta]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Kim]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Watson]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Sackner]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Response to bronchodilator drug administration by a new reservoir aerosol delivery system and a review of other auxiliary delivery systems]]></article-title>
<source><![CDATA[Am Rev Respir Dis]]></source>
<year>1982</year>
<volume>126</volume>
<page-range>670-675</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Newhouse]]></surname>
<given-names><![CDATA[MT]]></given-names>
</name>
<name>
<surname><![CDATA[Rufn]]></surname>
<given-names><![CDATA[RE]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Deposition and fate of aerosolized drugs]]></article-title>
<source><![CDATA[Chest]]></source>
<year>1978</year>
<volume>6</volume>
<page-range>939-943</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rubin]]></surname>
<given-names><![CDATA[Bruce K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Inhaled corticosteroids: devices and deposition]]></article-title>
<source><![CDATA[]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dolovich]]></surname>
<given-names><![CDATA[MB]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Lung dose, distribution and clinical response to therapeutic aerosols]]></article-title>
<source><![CDATA[Aerosol Sci Technol]]></source>
<year>1993</year>
<volume>18</volume>
<page-range>230-40</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Duarte]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Camargos]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Ef&#64257;cacy and safety of a homemade non-valved spacer for bronchodilator therapy in acute asthma]]></article-title>
<source><![CDATA[Acta Paediatr]]></source>
<year>2002</year>
<volume>91</volume>
<page-range>909-13</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<collab>GINA (Global Initiative for Asthma)</collab>
<article-title xml:lang="en"><![CDATA[Global Strategy for Asthma Management and Prevention]]></article-title>
<source><![CDATA[NIH]]></source>
<year>1995</year>
<volume>3659</volume>
<numero>2</numero>
<issue>2</issue>
</nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<collab>American Thoracic Society</collab>
<article-title xml:lang="en"><![CDATA[Standardization of Spirometry: 1994 Update]]></article-title>
<source><![CDATA[Am J Respir Crit Care Med]]></source>
<year>1995</year>
<volume>152</volume>
<page-range>1107-36</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Schultz]]></surname>
<given-names><![CDATA[RK]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Drug delivery characteristics of metered dose inhalers]]></article-title>
<source><![CDATA[J Allergy Clin Immunol]]></source>
<year>1995</year>
<volume>96</volume>
<page-range>284-287</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[McFadden]]></surname>
<given-names><![CDATA[Jr ER]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Improper patient techniques with metered dose inhalers: Clinical consequences and solutions to misuse]]></article-title>
<source><![CDATA[J Allergy Clin Immunol]]></source>
<year>1995</year>
<volume>96</volume>
<page-range>278-283</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ahrens]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Lux]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Bahl]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Han]]></surname>
<given-names><![CDATA[SH]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Choosing the metered dose inhaler spacer or holding chamber that matches the patient&#8217;s need: evidence that the speci&#64257;c drug being delivered is an important consideration]]></article-title>
<source><![CDATA[J Allergy Clin Immunol]]></source>
<year>1995</year>
<volume>96</volume>
<page-range>288- 294</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Barry]]></surname>
<given-names><![CDATA[PW]]></given-names>
</name>
<name>
<surname><![CDATA[OCallaghan]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Inhalation drug delivery from seven different spacer devices]]></article-title>
<source><![CDATA[Thorax]]></source>
<year>1996</year>
<volume>51</volume>
<page-range>835-840</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Finlay]]></surname>
<given-names><![CDATA[WH]]></given-names>
</name>
<name>
<surname><![CDATA[Zuberbuhler]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Mandl]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Particle size measurements for the space-chamber metered dose inhaler holding chamber compared with aerochamber and metered dose inhaler alone]]></article-title>
<source><![CDATA[J Aerosol Med]]></source>
<year>1997</year>
<volume>10</volume>
<page-range>213-219</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Newman]]></surname>
<given-names><![CDATA[SP]]></given-names>
</name>
<name>
<surname><![CDATA[Moren]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Pavia]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Little]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Clarke]]></surname>
<given-names><![CDATA[SW]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Deposition of pressurized suspension aerosols inhaled through extension devices]]></article-title>
<source><![CDATA[Am Rev Respir Dis]]></source>
<year>1981</year>
<volume>124</volume>
<page-range>317-320</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dolovich]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Rufn]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Corr]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Newhouse]]></surname>
<given-names><![CDATA[MT]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Clinical evaluation of a simple demand inhalation MDI aerosol delivery device]]></article-title>
<source><![CDATA[Chest]]></source>
<year>1983</year>
<volume>84</volume>
<page-range>36-41</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kim]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Eldridge]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
<name>
<surname><![CDATA[Sackner]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Oropharyngeal deposition and delivery aspects of metered-dose inhaler aerosols]]></article-title>
<source><![CDATA[Am Rev Respir Dis]]></source>
<year>1987</year>
<volume>135</volume>
<page-range>157-164</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dolovich]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Chambers]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of a pause prior to inhaling a MDI aerosol on drug availability through an open tube spacer]]></article-title>
<source><![CDATA[J Allergy Clin Immunol]]></source>
<year>1994</year>
<volume>93</volume>
<page-range>A39</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Barry]]></surname>
<given-names><![CDATA[PW]]></given-names>
</name>
<name>
<surname><![CDATA[OCallaghan]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The effect of delay, multiple actuations and spacer charge on the in vitro delivery of budesonide from the Nebuhaler]]></article-title>
<source><![CDATA[Br J Clin Pharmacol]]></source>
<year>1995</year>
<volume>40</volume>
<page-range>76-78</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wildhaber]]></surname>
<given-names><![CDATA[JH]]></given-names>
</name>
<name>
<surname><![CDATA[Devadason]]></surname>
<given-names><![CDATA[SG]]></given-names>
</name>
<name>
<surname><![CDATA[Eber]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Hayden]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
<name>
<surname><![CDATA[Everard]]></surname>
<given-names><![CDATA[ML]]></given-names>
</name>
<name>
<surname><![CDATA[Summers]]></surname>
<given-names><![CDATA[QA]]></given-names>
</name>
<name>
<surname><![CDATA[LeSouef]]></surname>
<given-names><![CDATA[PN]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of electrostatic charge, &#64258;ow, delay and multiple actuations on the in vitro delivery of salbutamol from different spacer devices]]></article-title>
<source><![CDATA[Thorax]]></source>
<year>1996</year>
<volume>51</volume>
<page-range>985-988</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Barry]]></surname>
<given-names><![CDATA[PW]]></given-names>
</name>
<name>
<surname><![CDATA[Robertson]]></surname>
<given-names><![CDATA[CF]]></given-names>
</name>
<name>
<surname><![CDATA[OCallaghan]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Optimum use of a spacer device]]></article-title>
<source><![CDATA[Arch Dis Child]]></source>
<year>1993</year>
<volume>69</volume>
<page-range>693-694</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wilkes]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Fink]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Dhand]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Selecting an accessory device with a metered-dose inhaler: Variable in&#64258;uence of accessory devices on &#64257;ne particle dose, throat deposition, and drug delivery with asynchronous actuation from a metered-dose inhaler]]></article-title>
<source><![CDATA[J Aerosol Med]]></source>
<year>2001</year>
<volume>14</volume>
<page-range>351-360</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kissoon]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Teelucksingh]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Blake]]></surname>
<given-names><![CDATA[KV]]></given-names>
</name>
<name>
<surname><![CDATA[Kesser]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Murphy]]></surname>
<given-names><![CDATA[SP]]></given-names>
</name>
<name>
<surname><![CDATA[Geller]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Plastic bottles as spacers for a pressurized metered-dose inhaler: in vitro characteristics]]></article-title>
<source><![CDATA[West Indian Med J]]></source>
<year>2001</year>
<volume>50</volume>
<page-range>189-93</page-range></nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zar]]></surname>
<given-names><![CDATA[HJ]]></given-names>
</name>
<name>
<surname><![CDATA[Weinberg]]></surname>
<given-names><![CDATA[EG]]></given-names>
</name>
<name>
<surname><![CDATA[Binns]]></surname>
<given-names><![CDATA[HJ]]></given-names>
</name>
<name>
<surname><![CDATA[Gallie]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Mann]]></surname>
<given-names><![CDATA[MD]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Lung deposition of aerosol. A comparison of different spacers]]></article-title>
<source><![CDATA[Arch Dis Child]]></source>
<year>2000</year>
<volume>82</volume>
<page-range>495-498</page-range></nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fowler]]></surname>
<given-names><![CDATA[SJ]]></given-names>
</name>
<name>
<surname><![CDATA[Wilson]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
<name>
<surname><![CDATA[Grifths]]></surname>
<given-names><![CDATA[EA]]></given-names>
</name>
<name>
<surname><![CDATA[Lipworth]]></surname>
<given-names><![CDATA[BJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparative in vivo lung delivery of hydro&#64258;uoroalkane salbutamol formulation via metered-dose inha ler alone, with plastic spacer, or with cardboard tube]]></article-title>
<source><![CDATA[Chest]]></source>
<year>2001</year>
<volume>119</volume>
<page-range>1018-1020</page-range></nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dolovich]]></surname>
<given-names><![CDATA[MB]]></given-names>
</name>
<name>
<surname><![CDATA[Ahrens]]></surname>
<given-names><![CDATA[RC]]></given-names>
</name>
<name>
<surname><![CDATA[Hess]]></surname>
<given-names><![CDATA[DR]]></given-names>
</name>
<name>
<surname><![CDATA[Anderson]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Dhand]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Rau]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
<name>
<surname><![CDATA[Smaldone]]></surname>
<given-names><![CDATA[GC]]></given-names>
</name>
<name>
<surname><![CDATA[Guyatt]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[American College of Chest Physicians, American College of Asthma, Allergy, and Immunology. Device selection and outcomes of aerosol therapy. ACCP/ACAAI evidence-base guidelines]]></article-title>
<source><![CDATA[Chest]]></source>
<year>2005</year>
<volume>127</volume>
<page-range>335-71</page-range></nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dubus]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
<name>
<surname><![CDATA[Dolovich]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Emitted doses of salbutamol pressurized metered-dose inhaler from &#64257;ve different plastic spacer devices]]></article-title>
<source><![CDATA[Fundam Clin Pharmacol]]></source>
<year>2000</year>
<volume>14</volume>
<page-range>219-24</page-range></nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rajkumar]]></surname>
</name>
<name>
<surname><![CDATA[Vatsa]]></surname>
<given-names><![CDATA[HK]]></given-names>
</name>
<name>
<surname><![CDATA[Gaur]]></surname>
<given-names><![CDATA[SN]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparative evaluation of market spacer and home made spacer in the management of bronchial asthma]]></article-title>
<source><![CDATA[J Assoc Physicians India]]></source>
<year>2002</year>
<volume>50</volume>
<page-range>397-9</page-range></nlm-citation>
</ref>
<ref id="B34">
<label>34</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Singhal]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Garg]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Arora]]></surname>
<given-names><![CDATA[HS]]></given-names>
</name>
<name>
<surname><![CDATA[Lodha]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Pandey]]></surname>
<given-names><![CDATA[RM]]></given-names>
</name>
<name>
<surname><![CDATA[Kabra]]></surname>
<given-names><![CDATA[SK]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Ef&#64257;cacy of a home-made spacer with acute exacerbation of bronchial asthma: a randomized controlled trial]]></article-title>
<source><![CDATA[Indian J Pediatr]]></source>
<year>2001</year>
<volume>68</volume>
<page-range>37-40</page-range></nlm-citation>
</ref>
<ref id="B35">
<label>35</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Panicker]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Sethi]]></surname>
<given-names><![CDATA[GR]]></given-names>
</name>
<name>
<surname><![CDATA[Sehgal]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparative ef&#64257;ciency of commercial and improvised spacer device in acute bronchial asthma]]></article-title>
<source><![CDATA[Indian Pediatrics]]></source>
<year>2001</year>
<volume>38</volume>
<page-range>340-348</page-range></nlm-citation>
</ref>
<ref id="B36">
<label>36</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zar]]></surname>
<given-names><![CDATA[HJ]]></given-names>
</name>
<name>
<surname><![CDATA[Brown]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Donson]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Brathwaite]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Mann]]></surname>
<given-names><![CDATA[MD]]></given-names>
</name>
<name>
<surname><![CDATA[Weinberg]]></surname>
<given-names><![CDATA[EG]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Home-made spacers for bronchodilator therapy in children with acute asthma: a randomized trial]]></article-title>
<source><![CDATA[Lancet]]></source>
<year>1999</year>
<volume>354</volume>
<page-range>979-982</page-range></nlm-citation>
</ref>
<ref id="B37">
<label>37</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fink]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Dhand]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Bronchodilator resuscitation in the emergency department: device selection]]></article-title>
<source><![CDATA[Respir Care]]></source>
<year>1999</year>
<volume>44</volume>
<page-range>1353-1374</page-range></nlm-citation>
</ref>
<ref id="B38">
<label>38</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Amirav]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Newhouse]]></surname>
<given-names><![CDATA[MT]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Metered-dose inhaler accessory devices in acute asthma]]></article-title>
<source><![CDATA[Arch Pediatr Adolesc Med]]></source>
<year>1997</year>
<volume>151</volume>
<page-range>876-882</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
