SciELO - Scientific Electronic Library Online

 
vol.29 número1APPLICATION OF FERRIPROTOPORPHYRIN BIOCRYSTALLIZATION INHIBITION TEST TO FIND ANTIPLASMODIAL COMPOUNDS IN THE FLORA OF THE "ZONGO VALLEY" - BOLIVIAESTUDIO DEL FRUTO COMESTIBLE DE LA ESPECIE VEGETAL GARCINIA MADRUNO índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

Compartir


Revista Boliviana de Química

versión On-line ISSN 0250-5460

Rev. Bol. Quim v.29 n.1 La Paz  2012

 

ARTÍCULO ORIGINAL

 

QUENCHING OF CERENKOV RADIATION FROM NATURALLY OCCURRING 40K BY DYES AS PHOTOMETRIC TECHNIQUE

 

 

Edgar A. Coronel C.

 

Universidad Mayor de San Andrés, Facultad de Ciencias Puras y Naturales, IIQ-Cota Cota, Andrés Bello and 27th.Street, La Paz-Bolivia

 

 


Keywords: Cerenkov radiation, Dyestuffs, Natural radioactivity, Liquid scintillation, Nuclear methods.

 

ABSTRACT

The beta emitter 40K isotope contained in KCl solutions, produces photons known as Cerenkov radiation measurable by liquid scintillation spectrometry. A set of dyestuffs and metal ion complexes showed quenching effects against Cerenkov light.

Studied systems follow the Stern-Volmer equation. Counting ratiosvs. quencher concentration [Q], are linear, yielding Ks.v constants. High Ks.v values indicate highly quenched systems. Congo red and Methylene blue havevalues 20.0xl04 M"1 and 2.27xl04 M"1 respectively. Crystal violet does not act as quenching agent in the range up to O.lrnM, and has a lowestvalue, about 10"4 M"1. There are linear correlations between visible absorbances atand counting ratios

Neither inorganic colorless salts as lead nitrate or zinc nitrate, nor pure solvents as acetonitrile, acetone, methanol and ethyl acetate showed quenching properties. As a result, a procedure suitable for dyestuff determinations based on quenching of Cerenkov radiation has been accomplished.


 

 

INTRODUCTION

High energy charged particles may enter into materials such as glass, plastic, or water, producing a bluish glow such as in a swimming pool nuclear reactor where energetic particles are emitted. Electrons traveling through water, move faster than the phase velocity of the light in that medium. Apollo astronauts observed flashes of light with their eyes shut attributed to Cerenkov emission caused by cosmic rays entering into their eyes,(l). The emitted light is known as Cerenkov radiation. In a wavelength intervalthe number of photons emitted as Cerenkov light is proportional towhere c is the light velocity, n is the refractive index of the medium and v the velocity of the particle (2),(3). Emitted photons have a continuous spectrum and the condition to produce Cerenkov radiation is giving by:

[1]

where

If relativistic electrons are involved, P can be written in terms of electron energy E:

For water « =1.332, then (3 should exceed 0.7508 to produce Cerenkov radiation by electrons. From equation [2], E = 263 KeV , a result for the lower energy threshold of Cerenkov radiation. Cerenkov light is emitted as a cone with angle 0 respect to the electron movement direction

[3]

Electrons with the threshold energy value will form a narrow cone. Therefore, there is a maximum angle of emission of 41.3° in water (4).

The content of 40K radioisotope in natural potassium is 0.0117% and decays with a half life of 1.277x109 years. Their decay modes include a 89.28% by p emission to the ground state of 40Ca and 10.72 % by electron capture toward an excited state of 40Ar which is followed by emission of gamma rays of 1.460 MeV, (5),(6). Pulse height shifts due to 32P observed by liquid scintillation spectrometry were related to absorbance of dyes,(7). Works faced with counting efficiency improvement involving dissolved organic compounds, solvents and color quenching have been made,(8),(9),(10). Quenching of Cerenkov radiation by colored substances concerning correlations between concentration and quenching effects including isotope free measurements using external standard were also published,(11),(12),(13). In a study dealing with meta-materials, Cerenkov light has been applied,(14).

Although quenching phenomenon theory has been applied to photochemical reactions where fluorescence are involved, the basic principles are useful as frame,(15),(16),(17). Fluorescence emission processes have been described in terms of Stern-Volmer equation:

[i]

in whichis a ratio of fluorescence quantum yields, in absence and in presence of a quenching agent â–  is the Stern-Volmer constant that involves a bimolecular quenching rate constant * and x 0 the excited state life time in the absence of quencher.is the molar concentration of quencher molecules. Instead of the quantum yield ratio; photon detector response ratiosare currently used. From linear relationships betweenand constants can be evaluated. The aim of this study is to report a series of data concerning Cerenkov light quenching effects exerted by different compounds playing the role of analyte in aqueous medium, using 40K. natural radioisotope as p emitter. A photometric technique to quantify organic dye molecules and metal ion complexes based upon quenched light are presented. In the frame of Stern-Volmer equation, detection limits, linear ranges and limitations are also evaluated.

RESULTS AND DISCUSSION

The Liquid Scintillation system enables Cerenkov light detection from 40K contained in potassium chloride salt dissolved in water. Figure 1 shows that counting rate is proportional to potassium chloride concentrations. Progressive additions of Methyl orange stock solution, cause a drop in counting rate or quenching along the tested range. However, each dye produces a different counting drop as a feature showing different slope values. Counting ratedue to KC1 solutions in absence of quencher or dye and counting rate ® measured after dye solution additions. From both readings ratio values asversus concentration m yielded straight lines from which KS-V constants were calculated. All studied systems were found to be linear over an established concentration range. Some Stern-Volmer plots are represented in figure 2 where different slopes may be seen. Congo red has a KS-V value of 20.0x104 M-1 a high value compared to the others, therefore it has a good quenching ability. The low KS-V value for Brilliant green, shows its low quenching effectiveness. On the other hand, Crystal violet has a lowest K S-V , around 10-4; such a striking difference points out that there is no quenching effect within the studied concentration range. A set of Stern-Volmer constants K S-V are shown in table 1, together with characteristic visible light absorption wavelengths and molar absorptivities.

On the basis of the analysis of visible absorption spectra, there is good correlation between absorbance values and Cerenkov light quenching ratios. Figure 3 illustrates some relationships between visible light absorbances at andvalues. These straight lines indicate fairly that Cerenkov photometry might be an amenable analytical technique. However, a question would be how to analyze mixed dyes.

Although there is nocorrelation between visible spectroscopy parameter s , the molar absorptivity arising from absorbances and, Stern-Volmer constants could be parameters alike e.

Fig.1. Detected differences between unquenched and quenched potassium chloride solutions by dissolved Methyl Orange.

Fig.2. Stern-Volmer quenching plots of Cerenkov radiation upon addition of different dyes.

Additions of pure solvents such as acetone, acetonitrile, methanol and ethyl acetate to KCl solutions separately, did not show quenching effects. Nevertheless, this fact could be an advantage because solvents other than water may be used in this kind of measurements. Dissolved lead and zinc nitrates are also unable to produce quenching . Neither high concentrations, nor long data acquisition times gave detectable quenching.

According to data, a high dye concentration does not cause further decrease of counting rate. Moreover, low counting rates due to high dye concentration would be an additional source of uncertainty. Detection limits considered as the lowest concentrations which can be detected, are roughly 2 or 3 p.p.m. A high detection limit belongs to the Crystal violet. The linear range column indicates the upper limit of concentration range with a correlation coefficients near 0.9990. Table 2 summarizes these parameters. This quenching technique not only has low detection limit, but also has good calibration linear relationships. Prepared standard solutions measured as

"unknowns" gave relative standard deviations (RSD) around 3-5%. However, it depends on the kind of dye measured and RSD values were all below 10%, but the Crystal violet. Despite of micromolar concentrations, these ones were also expressed in mg/L or p.p.m.

Table 1. Values of Stern-Volmer constants and visible spectra parameters of dyes and inorganic ions.

Compound/Dye

Ks-V, M-1

µmax , nm

e , cm-1 M-1

Malachite Green

7.44xl04

618

7.04x104

Murexide

2.07x104

525

6.64x103

Brilliant Green

2.38x104

625

6.30x104

Methylene Blue

2.27x104

665

8.52x104

Methyl Orange

16.1x104

505

1.64x104

Congo Red

20.0x104

497

5.83x104

Methyl Red

15.2x104

437

1.60x104

Neutral Red

9.91x104

540

2.96x104

Eosin Y

6.84x104

516

8.23x104

Bromophenol Blue

4.81x104

589

3.18x104

Crystal Violet

1.85x10-4

589

7.36x104

K Permanganate

1.14x104

525

2.61x103

K Dichromate

2.61x104

400

1.48x103

Cu(II)(NH3)42+

2.90x103

618

60

Fe(III)SCN 2+

1.72x104

469

3.08x104

Fig.3. Correlations between visible light absorbances and Cerenkov light quenching ratios.

At zero quencher concentration, counting efficiency E average out to 55%. Background data B has been determined before each series giving 55 CPM in average. In spite of a low value of so called Figure of Merit, (E2/B) =55, it can be improved by increasing the KCl concentration and hence the counting efficiency E.

For random processes such as radioactivity, the 2c error can be expressed as, where N is the total net counts,(18). Therefore, an increase of KCl content in a factor of 2 or 3 will give 2c error less than 10 percent. Another way to do this would be increasing counting time in order to improve the accuracy of data. Counting data were not influenced by inorganic potassium salts used as quenchers because of their low concentrations. As photometric technique it is suitable for organic or organometallic dyestuffs and a wide range of chemical analytes that exhibit color in aqueous solutions, including natural dyestuffs even though these are complex mixtures,(19). Table 2. Parameters arising from Stern-Volmer relationships as calibration straight lines.

Dye/Compound

Detection limit, p.p.m.

Linear range, p.p.m.

Linear regression coefficient

Malachite Green

1.9

13.9

0.9938

Murexide

7.9

56.0

0.9940

Brilliant Green

1.9

14.0

0.9970

Methylene Blue

1.9

14.0

0.9974

Methyl Orange

1.9

16.0

0.9979

Congo Red

2.0

14.0

0.9941

Methyl Red

1.9

14.0

0.9832

Neutral Red

3.9

24.0

0.9865

Eosin Y

1.9

11.9

0.9952

Bromophenol Blue

1.9

14.0

0.9920

Crystal Violet

31.0

-—

K Permanganate

1.9

14.0

0.9890

K Dichromate

2.0

14.0

0.9976

Cu(II)(NH3)42+

3.1

22.0

0.9882

Fe(III)SCN 2+

1.1

10.0

0.9976

Figure 4 illustrates µÂ¿-f constants as a function of maximum of visible light absorbance wavelengths of chosen dyes or compounds, and resembles a spectrum. However, it only shows that Congo red is the best quencher of Cerenkov photons than the other ones.

Fig.4. Stem-Volmer constants as a function ofof selected dyes or compounds.

On the other hand, Methylene blue and Brilliant green are worst quenchers. Cerenkov radiation as a shock wave, has a light frequencies composition larger toward the violet range. That is why the Cerenkov light is bluish in water. Experimental data show that blue solutions transmit blue light or does not quench it, and the other wavelengths are absorbed. Measurements of Cerenkov spectra for different radioisotopes by using color filters covering the interval 410-796 nm have been reported,(20). Different aqueous dye solutions working as filters could be another method to obtain the Cerenkov spectrum of 40 K . Among theoretical concerns about Cerenkov spectra fittings for reduced intensities in the near-ultraviolet region, a work has been published, (21 ).A reduction in Cerenkov radiation intensity can be caused by certain number of processes. Since the Stern-Volmer equation is obeyed , the main process involved is a collisional or dynamic quenching. In this case, electrons as fluorophores have contact with molecules of a dye or an inorganic anion. An important factor which contributes to the quenching phenomenon involves compounds with a high degree of conjugation that absorb visible or ultraviolet light. In the present case, Congo red has a large conjugated system than Crystal violet or Malachite green which are structurally related as substituted triphenylmetanes,(22). Since most of the tested dyes are acid-base indicators, it is important to take care pH conditions established experimentally.

EXPERIMENTAL SECTION

Cerenkov light due to beta emissions from 40K were detected and counting rate measurements were carried out on a Liquid Scintillation Spectrometer Beckman 1800 at room temperature. Before routine counting, a program was activated on the instrument, in order to eliminate a warning concerning calibration and its performance was verified with Beckman standards of 14C and tritium. For low activities, a Beckman calibration standard sample for background has been measured before each run. Beckman brand 20 mL vials of linear high density polyethylene were chosen because of low background. Polyethylene vials are suitable for this kind of measurements as was demonstrated in an earlier paper concerning counting efficiency,(23).

The liquid scintillation system consists of two photomultiplier tubes positioned face to face into a counting chamber provided with a reflector arranged in a very closegeometry. Electrical signal outputs from photomultipliers are connected to a coincidence and summing circuit. Events into a liquid sample that are sensed by both tubes within the resolving time are considered flash lights or scintillation pulses. A detection response range was determined by using dissolved potassium chloride at different concentrations, up to 1.20 g KCl/10 mL water. Linear relationships between counting readings in counts per minute (CPM) and KCl contents were obtained.In order to assess counting rates, a concentration of 0.500g KCl/10 mL water was prepared as active solvent. Potassium chloride Riedel code 12636 and MiliQ quality water were used. The following dyes and compounds from Merck, Baker and Riedel were tested: Eosin Y, Brilliant green, Neutral red, Methyl red, Malachite green, Murexide, Bromophenol blue, Congo red, Methyl orange, Methylene blue, Crystal violet, Potassium permanganate, Potassium dichromate, Lead nitrate and Zinc nitrate. Complex ions such as Fe(III)SCN2+ and Cu(II)(NH3)42+ were prepared in solution according to stoichiometric quantities. Acetonitrile, acetone, ethyl acetate and methanol, as pure solvents were also tested, adding volumes in the same amounts of dye solutions. When measuring samples, background readings were mandatory in order to correct counting data and it has been made by counting 10 mL of pure water. Blanck samples or KCl solutions without any dye, gave counting rates Ro in counts per minute (CPM), after background corrections. Stock solutions of dye 0.1% in weight were prepared. Since dye purities are less than 100%, corrections have been made for every compound. To different vials containing 10 ml of KCl solutions, and by using an Eppendorf micropipette; a stock dye solution was added in increments of 20 µL up to160 or 180µL, then quencher concentration is progressively increased. In an other way, to a unique vial containing 10 mL of KCl solution; a dye solution was added using the above mentioned volumes. In the first case, each vial is counted separately and in the second one, only one vial is counted after an addition. Either serial samples or a vial in which concentrations are varied, gave same readings within experimental deviations. Counting rates were measured during one minute and repeated a minimum of three times. Furthermore, readings were only averaged without taking into account random variations because radioactive decay phenomenon, although instrument readings are accompanied by standard deviations c. Standards and samples were handled into a shaded area because exposed vials to the direct sun light can cause counting rate variations. This effect has been verified with empty and filled vials.

A standard pH-meter provided with a glass-calomel electrode was used for measuring pH of solutions. Measured pH values were in the range from 5.50±0.20 at 20°C. Dissolved oxygen has not been removed from solutions. Counted serial samples were also measured by visible spectrophotometry at their maximum absorbance wavelengths using a Spectronic model Helios Alfa double beam spectrophotometer. A pair of matched silica cells of 10.0 mm of optical path length was useful.

ACKNOWLEDGEMENTS

The author thanks Centro de Investigaciones Nucleares Viacha (IBTEN), for use of the Liquid Scintillation Spectrometer. Isaac Luna and Samuel Fernández are gratefully acknowledged for providing assistance in the experimental section. Society for

Applied Spectroscopy (USA), is also thanked for presenting to the author and this work at Pittsburg Conference 2011 in Atlanta, Georgia.

 

Notes

*Corresponding author: edgar-coronel@daad-alumni.de

 

REFERENCES

(1) Fazio G.G., Jelley J.V. and Charman W.N., Nature, 1970,228, 260        [ Links ]

(2) M. R. Wehr, J.A. Richards and T.W. Adair, "Physics of the Atom", Addison-Wesley Publ.Co., Reading, Massachusetts, 1980.        [ Links ]

(3) H. Semat, "Física Atómica y Nuclear", Aguilar S.A., Madrid,1971        [ Links ]

(4) H.H. Ross, Analytical Chemistry, 1969, 41, 1260        [ Links ]

(5) D.R. Lide- H.P.R. Frederikse, Eds., CRC Handbook of Chemistry and Physics, 76th Edition 1995-1996, CRC Press, Boca Raton, Fl.        [ Links ]

(6) J. K. Tuli, Nuclear Wallet Cards, National Nuclear Data Center, Brookhaven National Laboratory, N. York, 2000        [ Links ]

(7) L.I. Wiebe, A.A. Noujaim and C. Ediss, The Intl. J. Apl. Radiat. Isotopes, 1971,22, 463        [ Links ]

(8) G.V. Ginkel, Intl. J. of Applied Radiation and Isotopes,1980,31,307        [ Links ]

(9) T. Satoh , K. Hasegaua, J. Radioanal. Nucl. Chem., Letters 1988, 128, 409        [ Links ]

(10) A. Grau Carles, et al., Nuclear Instr. and Methods in Physics Research,1993, 334, 2        [ Links ]

(11) F. Kulcsar, Journal of Radioanalytical Chemistry, 1979, 49, 171        [ Links ]

(12) C. Gonzales-Gomez, et al., J. of Radioanalytical Chemistry, 1983, 77, 1        [ Links ]

(13) G. Manjón et al., Advances in Liquid Scintillation Spectrometry, Ed. by Siegund Mobius,2002        [ Links ]

(14) S. Zhang and X. Zhang, Physics, 2009, 91,2        [ Links ]

(15) R.B. Cundall and A. Gilbert, "Photochemistry", Appleton-Century Crofts, New York,1970        [ Links ]

(16) N. J. Turro, "Modern Molecular Photochemistry", University Science Books, Sausalito, California, 1991.        [ Links ]

(17) J.R. Lakowicz, "Principles of Fluorescence Spectroscopy", Third Edition, Springer,N.York,2006        [ Links ]

(18) E.C. Long, "Liquid Scintillation Counting Theory and Techniques", Beckman Instruments, Irvine , California,1977        [ Links ]

(19) H.Schweppe, "Handbuch der Naturfarbstoffe", ecomed Verlagsgesellschaft, Landsberg/Lech, 1993        [ Links ]

(20) F. Kulcsar, D. Teherani and H. Altmann, J. of Radioanalytical and Nuclear Chemistry,1982,68,161        [ Links ]

(21) L. Fulop and T. Biró, Intl. J. of Theoretical Physics, 1, 31, 1992        [ Links ]

(22) D. Marcano, "Introducción a la Química de los Colorantes", Ed. Reverté Venezolana,Caracas, 1990        [ Links ]

(23) M. Takiue, T. Natoke, H. Fujii and T. Aburai, Applied Radiation and Isotopes,1996,47,123 Downloadable from: Revista Boliviana de Química. Volumen 29 N°1. Año 2012 http://www.bolivianchemistryjournal.org, http://www.scielo.org, http://www.scribd.com/bolivianjournalofchemistry        [ Links ]

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons