SciELO - Scientific Electronic Library Online

 
vol.60 número1Protocolo de Durán modificado en rehabilitación precoz de lesiones tendinosas flexoras de la mano índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

Compartir


Cuadernos Hospital de Clínicas

versión impresa ISSN 1562-6776

Resumen

DURAN-CALLE, J J  y  CRISPIN-NINA, D. Clinicaland ultrasonographic correlation with the intra-operative findings ofpatients with diagnosis of division of muff rotador in the service of traumatology of the hospital obrero n° 1, during period 2010-2014. Cuad. - Hosp. Clín. [online]. 2019, vol.60, n.1, pp.11-16. ISSN 1562-6776.

Abstract Introduction: A great part of the adult population suffers shoulder pain at some moment of life. Leaving aside direct neoplastic systems and traumatic diseases, one ofthe causes of pain of shoulder is the inflammatory or degenerative pathology of the muff rotator, which can result in an important functional limitation. Objective: Determining the degree ofclinicaland ultrasonographic correlation with the intra-operative findings in patients with yielding-point diagnosis of muff rotator in the service of Traumatology of the Hospital Obrero N° 1, during the period 2010-2014. Material and methods: Cross-sectional descriptive and analytical study. 56 patients of both sexes were surveyed, inpatients in the service of Traumatology y Orthopedic ofthe Hospital Obrero N° 1, during the period January 1 of 2010 to December 31 of 2014. The clinical assessment was carried out (maneuver of Jobe and maneuver of Yocum) and ultrasonographic and the results were compared with the intra operative findings, in order to determine the value and security of the clinic and the echography. Results: It is determined that the diagnostic test has higher validity (Sensitivity: 92,7-87,8% and specificity: 73,3-60%) and certainty (Positive Predictive Value: 90,5-85,7% and Negative Predictive Value: 78,6-64,3%) than the diagnostic ultrasonographic test (Sensitivity: 85.4%, Specificity: 66.7%, Positive Predictive Value: 87.5% and Negative Predictive Value: 62.5%). Conclusions: It is determined that there is a clinical and ultrasonographic correlation with the intra operative findings in patients with yielding-point diagnosis of muff rotator at the service of Traumatology of the Hospital Obrero N° 1.

Palabras clave : Clinic; ultrasonography; findings intra-operative; muff rotator.

        · resumen en Español     · texto en Español     · Español ( pdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons