SciELO - Scientific Electronic Library Online

 
vol.41 número3Uso da mistura de hélio e oxigênio no estudo da ventilação de crianças com doença pulmonar obstrutiva crônica índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Não possue artigos similaresSimilares em SciELO

Compartilhar


Revista de la Sociedad Boliviana de Pediatría

versão On-line ISSN 1024-0675

Resumo

PIVA, Jefferson et al. High frequency oscillation ventilation compared to conventional mechanical ventilation plus exogenous surfactant replacement in rabbits. Rev. bol. ped. [online]. 2002, vol.41, n.3, pp.154-160. ISSN 1024-0675.

Objectives: (a) to evaluate the effect on oxygenation and ventilation of rabbits with induced surfactant depletion when they are submitted to a conventional mechanical ventilation, plus a small dose of exogenous surfactant; (b) to compare this group with another group submitted to a High Frequency Oscillation (HFO) without exogenous surfactant administration. Methods: Twenty New Zealand White rabbits weighing (+ 3 kg) were anaesthetized and artificially induced to a endogenous surfactant depletion by successively lung lavage with normal saline (aliquots of 25 ml/kg) until to reach a persistent PaO2 less than 100 mmHg when submitted to a mechanical ventilation in a pressure control mode with a target tidal volume of 10ml/kg, PEEP of 5cm H2O, FiO2 1.0, respiratory rate 30/min, and inspiratory time of 0.65 s. Then the rabbits were divided in (a) CMV+S group, submitted to a conventional mechanical ventilation plus exogenous surfactant replacement; (b) HFO group, submitted to a High Frequency Oscillation Ventilation. Arterial blood gases were measured at control period, post lung lavage, 15, 16 and 120 minutes after treatment started. The groups were compared using Student t test. Results: The post lung lavage PaO2 in both groups was lower than 50mmHg (p=0.154), increasing after 15 min of treatment to 254 mmHg (CMV+S) and 288 mmHg (HFO, p=0.626). The PaO2 at 60 and 120 minutes were higher (p=0.001) in the HFO group (431 e 431 mmHg) when compared with the CMV+S group, which showed a progressive fall (148 e 126 mmHg). At 60 minutes of treatment, the PaCO2 was lower (p=0.008) in the CMV+S group (29 versus 41 mmHg). Conclusions: In ARDS animal model a protect mechanical ventilation strategy as HFO by itself promotes a fast and persistent increase in the oxygenation, with superior levels than those observed in animals treated with conventional mechanical ventilation plus exogenous surfactant replacement.

Palavras-chave : J. pediatr. (Rio J.) 2000; 76 (5): 349-356; surface-active agents; artificial respiration; hypoxemia; respiratory insufficiency.

        · resumo em Português     · texto em Português

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons